IMD 100 Integration manual 4189360015 Rev. G
Operational procedures
Page 130 of 243
The IMD goes back to “Normal operation” state, turns the brake output (X2) off, and changes the
“Brake output” LED indication in the IMD Manager to off.
9.2
Changing actual position value (Pos. preset)
It is possible to change the value of the actual position value. The position is a 32 bits value where the
low 16 bits indicates the position of the motor within one revolution. The high 16 bits indicates the
number of revolutions. This function is normally used to reset the revolution counter to zero, when
using speed profile for safety run, or calibrating zero revolutions for use with the Virtual limit switches
(VLMS).
The following figure shows how the actual position is changed when the position is changed to zero (in
both
“Position” and “Monitor and control” tabs):
9.2.1 Prerequisites
The IMD must be in Normal operation state, and the Device must be disabled (Reg. 0x51 bit 2 = 1).
Monitor and control
Position