11. Maintenance
WARNING!!!
Before carrying out any inspection, maintenance or reparation always
remove the plug from the socket !!
Daily
Inspect the unit visually for damage.
Repair damage, however slight, immediately, or have it repaired.
This is for your safety and to maximise the lifetime of the machine.
Also inspect the electricity cable.
If damaged, remove it immediately and have it repaired.
Your safety comes first!
Keep the nebuliser clean!! This reduces the risk of accidents, and works more
comfortable!
ATTENTION!
Clean carefully!!! Never use a high pressure cleaner!!
12. Trouble shooting
WARNING!
Repairs must be carried out by qualified personnel only. Use only
original spare parts. This guarantees the safety of the equipment!!
1) The fan bearings are noisy/not running smoothly.
Replace the bearings. Mount using a liquid thread locker.
2) The ventilator will not start
No voltage:
Turn on power / turn on regulator / replace fuse.
Voltage present: Carbon brush is worn
: replace the carbon brush.
3) Thermal protection stalls:
Clean / Replace the bearings / Replace the windings.
4) Nebuliser is not receiving water.
Check: the water flow / the control valve / clean the filter.