DEHACO MA2S Скачать руководство пользователя страница 5

 

5

© 2022 Dehaco B.V. • User and maintenance manual Ma2s 3-chamber decontamination shower • Version_2022-07_v1.0_EN

  

The contaminated room features an additional 

type of opening for fitting the Dehaco Bypass 

(Figure 4). This can be installed on any side of the 

contaminated room. 

 NB Ensure that the Dehaco Bypass is capable of 

air suction without obstruction. Always site it on an 

unobstructed side.

Figure 4 Opening Dehaco Bypass

If the openings have been installed correctly, then 

it will be possible to place the shower basin in the 

shower room (Figure 5). Ensure that the flaps hang 

down in the shower basin so that no water can get 

underneath the shower basin.

Figure 5 Shower basin

In order to be able to shower you need a water 

source, such as a Dehaco water management 

system.

4. CLEANING

Once the work for which the decontamination shower 

has been erected has been successfully completed, the 

decontamination shower must be cleaned. In the case 

of asbestos removal, cleaning should take place prior 

to the clearance measurement of the containment. 

Wipe the walls and floors with a damp cloth. If 

necessary, you can use an all-purpose cleaner. 

Pump all the water out of the shower basin and also 

wipe the basin with a damp cloth.

5. TRANSPORT AND STORAGE

Once the decontamination shower is fully dry on the 

inside, you can disassemble it. 

•  Remove the shower basin from the shower 

chamber. 

•  Remove the spacers from the chambers and place 

them back in the chamber along the door. 

•  Fold the sides to the inside and press the door 

sections against each other and fasten them at the 

top and bottom with the straps. 

•  Zip the doors closed.

 Caution: Transport the decontamination shower on 

its side and do not allow heavy objects to rest on the 

tarpaulin. 

Store the decontamination shower on its side or in a 

standing position in a dry environment. 

6. REPAIR AND MAINTENANCE

The following points can be repaired and maintained:

•  Hole in the tarpaulin: This can be repaired by 

positioning a new piece of tarpaulin over the hole 

and attaching it with adhesive. 

•  Zip getting stuck: This can be remedied by spraying 

the zip clean with air and lubricating it with WD40. 

You can take the decontamination shower to 

your point of purchase for any other repair and 

maintenance. 

 NB The decontamination shower will have to be 

clean when presented for repair and maintenance 

work. 

7. END OF LIFESPAN

The decontamination shower can be disposed of once 

it reaches the end of its life. In this regard, please 

comply with current regulations for recycling discarded 

products.

Ensure that the decontamination shower is cleaned 

prior to disposal. 

Содержание MA2S

Страница 1: ...1 Consisting of 2 parts with zip and side doors User and maintenance manual Version_2022_07_v1 0_EN Ma2s decontamination shower 3 chambers ...

Страница 2: ...2 Dehaco B V Kruisbaak 25 2165 AJ Lisserbroek NL 31 0 88 20 20 600 info dehaco nl www dehaco nl ...

Страница 3: ...ithout prior written permission from Dehaco B V This also applies to accompanying drawings and schematic displays where applicable At all times Dehaco B V reserves the right to make changes to the products and or their parts without prior notification This also applies to the contents of this manual For information about installation maintenance and repair not included in this manual we recommend ...

Страница 4: ... 1 that can be placed on the cams on the inside at the top and bottom In the shower chamber the spacers are only placed at the top because of the shower basin that must be placed there Figure 1 Position the spacers The decontamination shower consists of two parts The clean room section and the shower contaminated room section You can have these in a straight or L shaped set up The two sections can...

Страница 5: ...basin with a damp cloth 5 TRANSPORT AND STORAGE Once the decontamination shower is fully dry on the inside you can disassemble it Remove the shower basin from the shower chamber Remove the spacers from the chambers and place them back in the chamber along the door Fold the sides to the inside and press the door sections against each other and fasten them at the top and bottom with the straps Zip t...

Страница 6: ...0 68 High 10 SCI WORK EQUIPMENT REQUIREMENTS For the Dutch market the decontamination shower meets the requirements in relation to dimensions Combined with the Dehaco bypass and heating it also meets the Sci Work Equipment Requirements On this see the conformity statement 11 TECHNICAL SPECIFICATIONS 6010 0113 Ma2s decontamination shower zip 2 1 3 75x225x190cm Dimensions 75x225x190cm Dimensions per...

Страница 7: ...7 2022 Dehaco B V User and maintenance manual Ma2s 3 chamber decontamination shower Version_2022 07_v1 0_EN ...

Страница 8: ...Dehaco B V Kruisbaak 25 2165 AJ Lisserbroek NL 31 0 88 20 20 600 info dehaco nl www dehaco nl Dehaco B V Address head office Kruisbaak 25 2165 AJ Lisserbroek Netherlands T 31 0 88 20 20 600 E info dehaco nl www dehaco nl ...

Отзывы: