Basic control panel
IMPORTANT!!
First step is always to start the water
supply. The atomizer can only function a
short time without water, and the
electronics needs the water as coolant
9.2 Operation with basic control panel
From left to right:
EMERGENCY STOP
will be illuminated if the
emergency stop has been activated. To reset the
emergency stop: first pull the red emergency stop
button on the water nebuliser, then press the button
on the control panel for resetting the system. The
TERA can now be restarted.
FREQ. ERROR
will be illuminated if an error has
occurred in the frequency converter. Press the reset
button.
Turn off the machine, remove the plug from the
connector, wait 1 minute and then restart the
machine.
PHASE ERROR
will be illuminated by a phase problem.
First check the extension lead(s), the power supply
(generator) and fuses. Then restart the TERA.
When the TERA comes to a standstill after a (short)
running period, replace the extension leads by
extension leads with a larger cross-section. Especially
for larger distances the cable cross-section is an
important item!!
MANUAL / AUTO
makes it possible to choose between
a fixed position and automatic swiveling. The button
will light up in green when in AUTO setting.
1()0
On/Off switch for the TERA water nebuliser.
FAN 1/2/3
Configure Eco/ Eco-Boost / Power-Boost.
ROTOR
1/2/3
Configure
droplet
size:
Large/Medium/Fine.
←()→
Manually configure swivel angle to the
left/right.
This button has been placed on the version with
electrical height adjustment:
← →
Manually configure swivel angle to the left/right.
↕
Manually
configure
swivel
angle
upwards/downwards.