Calibration of the temperature probes.
To make the temperature probe calibration ensure you have the
needed precision resistors (3 x 162 ohms ; 3 x 100 ohms 0,1%
precision) and the 6 points connectors.
•
After entering the password, the display shows
.
•
Remove the connector of the temperature probe from the
CPU board.
•
Insert the connector with the low value precision resistors.
•
Press
.
•
The display shows
.
•
Remove the low value resistors.
•
Insert the connector with the high value resistors.
•
Press
.
•
Remove the resistors and put back the connector with the
temperature probe.
64
No
Display the temperature on the front of the drawers for all dryer
sections.
65
(see “
Note”
)
Correction of the dryer 1 lateral temperature Before entering the
new value, it is required to check the difference between the
temperature displayed and the temperature inside the dryer. For
example if the value displayed is 60°C and the temperature inside
is 56°C, 4 °C will have to be subtract from the value displayed in
P56 prior to re-enter the new value. Has to be done when the dryer
is in the regulation phase.
66
(see “
Note”
)
Correction of the dryer 2 lateral temperature Before entering the
new value, it is required to check the difference between the
temperature displayed and the temperature inside the dryer. For
example if the value displayed is 60°C and the temperature inside
is 56°C, 4 °C will have to be subtract from the value displayed in
P56 prior to re-enter the new value. Has to be done when the dryer
is in the regulation phase.
67
(see “
Note”
)
Correction of the dryer 3 lateral temperature Before entering the
new value, it is required to check the difference between the
temperature displayed and the temperature inside the dryer. For
example if the value displayed is 60°C and the temperature inside
is 56°C, 4 °C will have to be subtract from the value displayed in
P56 prior to re-enter the new value. Has to be done when the dryer
is in the regulation phase.
68
No
Buzzer time
69
Init of the memory
Note: Temperature calibration for one section of dryer always refers to 2 specific
programs: one for the lateral temperature (front and back of the drawer) and one for the
temperature in the middle of the drawer.
Содержание CONCEPT 501
Страница 1: ...CONCEPT 501 DRYER PRE INSTALLATION INSTALLATION USER S MANUAL TECHNICAL MANUAL ...
Страница 13: ...TECHNICAL MANUAL Technical Manual Eng Version 3 1 Page 13 27 Spare part list ...
Страница 14: ...TECHNICAL MANUAL Technical Manual Eng Version 3 1 Page 14 27 ...
Страница 15: ...TECHNICAL MANUAL Technical Manual Eng Version 3 1 Page 15 27 ...
Страница 16: ...TECHNICAL MANUAL Technical Manual Eng Version 3 1 Page 16 27 ...
Страница 18: ...TECHNICAL MANUAL Technical Manual Eng Version 3 1 Page 18 27 Electrical Scheme ...
Страница 19: ...TECHNICAL MANUAL Technical Manual Eng Version 3 1 Page 19 27 ...
Страница 20: ...TECHNICAL MANUAL Technical Manual Eng Version 3 1 Page 20 27 ...
Страница 21: ...TECHNICAL MANUAL Technical Manual Eng Version 3 1 Page 21 27 ...
Страница 22: ...TECHNICAL MANUAL Technical Manual Eng Version 3 1 Page 22 27 ...
Страница 23: ...TECHNICAL MANUAL Technical Manual Eng Version 3 1 Page 23 27 ...
Страница 24: ...TECHNICAL MANUAL Technical Manual Eng Version 3 1 Page 24 27 ...