Unless there is an abnormal condition, 
do not attempt to remove the gas burner 
taps. You must call an authorised 
service agent if it is necessary to 
change the taps. 

New injectors have their position 
marked on their packing or refer to the 
Injector table. 

 

Reduced gas flow rate setting for taps 

1.  Ignite the burner that is to be adjusted and turn the 

knob to the reduced position. 

2.  Remove the knob from the gas tap. 
3.  Use  an  appropriately  sized  screwdriver  to  adjust 

the flow rate adjustment screw. For LPG (Butane - 
Propane)  turn  the  screw  clockwise.  For  natural 
gas,  you  should  turn  the  screw 

counter-

clockwise 

once.  The  normal  length  of  a  straight 

flame in the reduced position should be 6-7 mm 

4.  If the flame is higher than the desired position, turn 

the  screw  clockwise.  If  it  is  smaller  turn 
anticlockwise. 

5.  For  the  last  control,  bring  the  burner  to  both  the 

high-flame  and  reduced  positions  and  check 
whether the flame is on or off. 

 

Depending  on  the  type  of  gas  tap  used  in  your 
appliance the adjustment screw position may vary. 

Flow rate adjustment screw 

Gas conversion 

In order to have the appliance's gas type changed, all 
the  injectors  must  be  changed  and  the  flame 
adjustment  for  all  valves  must  be  set  at  the  reduced 
flow rate position. 
 

Changing the injectors 

1.  Take off burner cap and burner body. 
2.  Unscrew injectors by turning them 

counterclockwise. 

3.  Fit new injectors. 
4. Check all connections for secure fitting and 

tightness.  

DANGER Risk of 
explosion or poisoning 
by unprofessional 
installation. 

Gas 

conversion must only be 
carried out by a 
registered installer. 

 

DANGER Risk of 
explosion! 

Before starting any work 
on the gas installation, 
shut off the gas supply

 

1

  Spark plug 

2

  Injector 

3

  Burner 

 

If the gas type of the appliance is 
changed,  then  the  rating  plate 
that  shows  the  gas  type  of  the 
unit must also be changed. 

 

 

Содержание DGS170

Страница 1: ...tions in this manual are subject to change without notice Record in the space below the listed information for future reference SERIAL NUMBER DATE OF PURCHASE PURCHASED FROM PERMIT NUMBERS 1037 48 1 R...

Страница 2: ...with information on how to operate and care for your appliance to gain the maximum benefit from it We trust you will enjoy years of trouble free use EXPLANATION OF SYMBOLS Throughout this User Manual...

Страница 3: ...chanism 13 Electrical installation 14 Gas connection 14 Leakage control 15 Final check 15 Gas conversion 16 Package information 17 Future transportation 17 Disposing of the old appliance 17 4 Preparat...

Страница 4: ...For this reason technical specifications text and illustrations in this manual are subject to change without notice Figures in this manual are schematic and may not match your appliance exactly 5 Tray...

Страница 5: ...g and for placing food to be baked roasted or cooked in casserole dishes on to the desired rack Identification table Position hob zone 2000 W Rear left RL 3000 W Front left FL 1000 W Front right FR 20...

Страница 6: ...arthed in accordance with the local regulations If the supply cord is damaged it must be replaced by the manufacturer its service agent or similar qualified persons in order to avoid a hazard Do not o...

Страница 7: ...the oven door and frame and do not route it over hot surfaces as the cable insulation may melt and cause a fire as a result of a short circuit Make sure that the function knobs are switched off after...

Страница 8: ...away from children Please ensure that the packaging material is disposed of in a responsible manner Safety when working with gas Any work carried out on gas equipment and systems may only be done by a...

Страница 9: ...rgency telephone numbers and safety measures from your local gas provider in case of a gas smell In the event of a pan fire Switch off the Gas supply Smother the flames with a blanket or damp cloth Bu...

Страница 10: ...etc by hanging them on the oven door handles This product should also not be used for room heating purposes The manufacturer shall not be liable for any damage caused by improper use or handling error...

Страница 11: ...of any size The kitchen furniture or equipment on the other side may only be of the same size or smaller Any kitchen furniture next to the appliance must be heat resistant 100 C min Before installatio...

Страница 12: ...27 for use with NG and any fire department regulations and or local bylaws applicable to the area If in doubt check with the relevant authority before undertaking the installation Upon completion of t...

Страница 13: ...to allow for an area to work in Using a 8 0 mm concrete bit drill a hole at the marked position Using the Stability hook and anchor sleeve B firmly secure B to the wall Slide the stove back in positio...

Страница 14: ...t not be used for lifting or moving the appliance DANGER Risk of electric shock Before starting any work on the electrical installation please disconnect the appliance from the mains supply DANGER Ris...

Страница 15: ...e no further leaks 1 Hose tip LPG 2 Hose tip NG 3 Safety hose 4 O ring gasket 5 Clamp Push the appliance towards the kitchen wall Caution Never use a naked flame to check for gas leaks DANGER Risk of...

Страница 16: ...e last control bring the burner to both the high flame and reduced positions and check whether the flame is on or off Depending on the type of gas tap used in your appliance the adjustment screw posit...

Страница 17: ...re dangerous to children Keep packaging materials in a safe place out of reach of children Packaging materials of the appliance are manufactured from recyclable materials Do not dispose of the packagi...

Страница 18: ...rge flame symbol indicates the highest cooking power and small flame symbol indicates the lowest cooking power In the turned off position top gas is not supplied to the burners Igniting the gas burner...

Страница 19: ...again 4 Keep the gas oven control knob pressed for 3 to 5 seconds Repeat the process until the emanating gas is ignited 5 Keep the gas oven control knob pressed for another 3 to 5 seconds Be sure that...

Страница 20: ...ection Never use cleaning products containing abrasive materials as these could damage the decorative and informative paint applications Remove the burners and wipe them with a thin damp cloth or a no...

Страница 21: ...fully lift the socket and loosened brass gas jet from the central burner tube 4 Insert the Classic pin into central hole of the jet and slide it up and down until the jet is free of accumulated dirt 5...

Страница 22: ...er cap properly Gas valve is closed Open gas valve Gas cylinder is empty when using LPG Replace the gas cylinder The burners will not light The burners will not light The gas pipe is twisted bent or k...