Permanent installation 

Important information for the user. 

This appliance may only be installed by a registered LP Gas installer. 

All registered installers 

are issued with a card carrying their registration number. Ask to be shown this card before allow-
ing the installation work to commence and make note of the               Installer QCC number. Upon 
completion of the installation, the installer is required to explain the operational details of the ap-
pliance together with the completion certificate.  Pay particular attention to the operation of the 
isolation or shut-off valve in the gas supply line to the appliance. You should sign for acceptance 
of the installation when the installation is completed to your satisfaction. Note that your invoice is 
required in the event that you wish to make a guarantee claim. 

 

Important information for the installer 

Pl

ease refer to installation instructions in this leaflet and in the operating manual supplied.  

This appliance may only be installed by a registered LP Gas installer registered with the Liq-
uefied Petroleum Gas Association of Southern Africa.  

The appliance must be installed in accordance with the requirements of SANS 10087-1 and any 
fire department regulations and/or local bylaws applicable to the area. If in doubt check with the 
relevant authority before undertaking the installation. Upon completion of the installation you are 
required to fully explain and demonstrate to the user the operational details and safety practices 
applicable to the appliance and the installation. 
When the installation is completed, please print your details below.

 

Name 

………………………………………. 

Company 

………………………………………. 

Registration number 

………………………………………. 

Telephone number 

………………………………………. 

Caution: 

Never use a naked flame to check for gas leaks 

Check for gas leaks after installation and whenever a new or re-filled gas bottle is used for 
the first time. 
Ensure that the control knobs on the hob are in the OFF position. 
Open the valve on the Gas bottle. 
Using a small paint brush, apply some soapy water to all the connections. 
If there is a leak, bubbles will appear. 
If this happens, close the valve on the gas bottle. 
Check and tighten the connections immediately. 
Repeat the procedure to ensure that there are no further leaks. 

Maintenance and servicing 

Service intervals. 

Every twelve months the stove should be serviced by a Defy Service agent to ensure continued effi-
cient and safe operation. 
Note: If required, the cleaning of the valves should only be carried out by a qualified Defy technician. 
i.e. Burner not functioning correctly.  
Removable burner parts should be washed weekly  with hot water and detergent. 
Take care to remove any encrustations and ensure that the burner holes are  clear. 
The gas hose and valve condition should be inspected for leaks every time the gas bottle is re-filled. 

Содержание DGS 154

Страница 1: ...is appliance is not intended for use by persons including children with reduced physical sensory or mental capabilities or lack of experience and knowl edge unless they have been given supervision or...

Страница 2: ...ance must be earthed The manufacturer and the seller do not accept responsibility for any damage due to incorrect installation or electrical connection Model DGS 156 Electrical current is required for...

Страница 3: ...inders with a minimum capacity of 19kg be used Regulator Not supplied A 2 8 kPa LPG gas regulator which complies with SANS 1237 must be used This appliance uses LPG Liquid Petroleum Gas also known as...

Страница 4: ...k with the relevant authority before undertaking the installation Upon completion of the installation you are required to fully explain and demonstrate to the user the operational details and safety p...

Страница 5: ...again turn off the control knob to the affected burner and consult the nearest Defy service technician who will advise you Ventilation Room ventilation is vital for the efficient performance of the ap...

Страница 6: ...ntinued efficient and safe operation This may be done using a Gas Jet Cleaning Kit which may be pur chased from your nearest Defy Service Centre The kit comprises of a sliding T bar A a socket B and a...

Страница 7: ...6 3000 CapeTown Service defy co za DURBAN 35 Intersite Avenue Umgeni Business Park Durban 4051 Tel 031 268 3300 Durban Service defy co za EAST LONDON 16 Bowls Rd Arcadia East London 5201 Tel 043 743 7...

Страница 8: ...ss condition of these warranties that the purchaser takes due care and attention in the use and maintenance of the appliance Abuse misuse in conflict with operating in structions connection to incorre...

Отзывы: