Settings 

 Automatic Power 

This

 

setting

 

allows

 

selecting

 

mode

 

of

 

power

 

modulation.

 

Selecting

 

option

 

ON

 

the

 

stove

 

system

 

will

 

choose

 

power

 

(automatic

 

mode).

 

In

 

this

 

case

 

dont

 

appear

 

Menu

 

Customization

 

 

Power

 

 

Combustion

.

 

Setting

 

OFF

 

option

 

allow

 

user

 

choose

 

the

 

power

 

level

 

in

 

Customization

 

Level

 

 

Power

 

 

Combustion.

 

 

 

 

Menu Settings

 Keyboard Menu 

 

Display

 

menu

 

contains

 

functions

 

responsible

 

for

 

control

 

of

 

its

 

operations:

 

 

Lista

 

Adresow

 

(Address

 

list)

 

 

Contrast

 

 

Backlight

 

 

Tone

 

Przyciski

 

(Buttons

 

tone)

 

 

Modyfikacje (Modifications) Menu 

 Menu 

wyświetlacza (Display menu) 

 Lista 

Adresów (Address list) 

Address

 

list

 

contains

 

list

 

of

 

cooperating

 

devices

 

connected

 

with

 

the

 

controller.

 

Each

 

item

 

of

 

the

 

list

 

contains

 

address,

 

type

 

and

 

version

 

of

 

software.

 

Designation

 

of

 

types:

 

 

MSTR

  

 

master

 

device

 

 

INP

  

 

input

 

 

KEYB

  

 

Keyboard

 

 

OUT

 

 

output

 

 

CMPS

 

 

complex

 

equipment

 

 

SENS

 

 

sensor

 

 

COM

 

 

communication

 

link

 

 

Keyboard Menu 

 Contrast 

This

 

option

 

is

 

used

 

to

 

adjust

 

contrast

 

of

 

the

 

display

 

 

Keyboard Menu 

 Min Light 

This

 

screen

 

can

 

be

 

used

 

to

 

set

 

a

 

degree

 

of

 

screen

 

backlight.

 

 

Keyboard Menu 

Mute Keys 

Buttons

 

Tone

 

menu

 

allows

 

switching

 

on

 

and

 

off

 

a

 

sound

 

during

 

pressing

 

of

 

panel

 

control

 

buttons

 

 

Information screens 

Information

 

on

 

current

 

parameters

 

of

 

boiler

 

operation

 

are

 

displayed

 

on

 

two

 

screens

 

titled

 

Informacja

 

(Information)

,

 

which

 

are

 

recalled

 

by

 

 

buttons.

 

Screen

 

displayed

 

with

 

a

 

button

 

:

 

Exhaust

 

T.

 

 

temperature

 

of

 

flue

 

gas

 

Boiler

 

T.

 

 

water

 

temperature

 

in

 

heat

 

exchanger

 

Buffer

 

T.

 

 

water

 

temperature

 

in

 

buffer

 

tank

 

(DHW)

 

(if

 

installed)

 

Settings
Summer-Winter

Automatic Power

AUTOMATIC POWER

ON

<<

OFF

Menu Wyswietlacza
Lista Adresow
Kontrast

Podswietlenie

Tone Przyciski

1. FSYSR02000002.
2. -MSTR - FW 1.5 0
2.FSYSF04000035
6 - KEYB - FW 1.4.0

Contrast

+

-

8

Min Light

+

-

8

Mute Keys

ON

<<

OFF

Содержание NG01 HYDRO

Страница 1: ...operating manual controller NG01 HYDRO with control panel K100 adapted for operation with HYDROPELL dry stoves fired with pellet translation of original operating manual issue 1 September 2019 www pl...

Страница 2: ......

Страница 3: ...ation status 7 Alarms 8 Messages 8 User menu 9 Menu Customization 9 Menu Customization Power 9 Menu Customization Thermostats 9 Menu Customization Chrono 9 Menu Settings 11 Menu Settings Settings 11 M...

Страница 4: ...nel with antistatic cover Safety notice Prior to installation user should acquire knowledge of Environmental and safety standards Follow all local regulations inclusive of these given in the national...

Страница 5: ...e increase K5 exit to information screen value decrease Diodes Designation Icon Description L1 clock current time L2 signalling of activation of chrono mode L3 signalling of empty pellet container L4...

Страница 6: ...ting system The configuration comprises of three stages Selection of hydraulic system Selection of controlled device by output V2 P44 Selection of devices connected to inputs IN2 P77 IN3 P75 IN6 P78 a...

Страница 7: ...ted to IN2 IN3 IN6 IN7 inputs Device Paramete r Inputs IN2 P77 IN3 P75 IN6 P78 IN7 P82 None input not connected 0 Door sensor 2 Pellet thermostat 3 Ambient thermostat 4 Flow switch 5 Pellet level sens...

Страница 8: ...mmunication error Er17 Air flow adjustment failed Er18 No fuel Er23 Boiler of DHW sensor opened Er25 Cleaning motor damaged Er39 Damaged sensor of flowmeter Er41 Minimum flow of air in Control Checkin...

Страница 9: ...n Thermostats This menu allows changing values of temperature of stove thermostat Boiler set value is within the determined limits between the given Max and Min values Select required value of water t...

Страница 10: ...h the keys Confirm selected value with a key Repeat operations for the other fields Each cycle can be activated or blocked pressing a button Active time interval is marked by filling a bullet precedin...

Страница 11: ...m the controller Settings Remote control Switching on or switching off the control by remote module Settings Auger Calibration Calibration of endless screw allows changing speed of operation or durati...

Страница 12: ...er device INP input KEYB Keyboard OUT output CMPS complex equipment SENS sensor COM communication link Keyboard Menu Contrast This option is used to adjust contrast of the display Keyboard Menu Min Li...

Страница 13: ...for reaching of set water temperature decreasing at the same time portions of supplied pellet Work cycle After initiation of the firing the stove switches successively to the following operation modes...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...DEFRO Sp ka z ograniczon odpowiedzialno ci Sp k 00 403 Warszawa ul Solec 24 253 Manufacturing plant Ruda Strawczy ska 103 A 26 067 Strawczyn tel 41 303 80 85 fax 41 303 91 31 biuro defro pl...

Отзывы: