Menu Settings 

This

 

menu

 

contains

 

three

 

options:

 

 

Settings

 

 

additional

 

configuration

 

of

 

stove

 

operation

 

 

Keyboard

 

Menu–

 

setting

 

of

 

display

 

operation

 

parameters

 

 

System

 

Menu

 

 

access

 

after

 

entering

 

the

 

password;

 

menu

 

contains

 

options

 

set

 

by

 

the

 

fitter

 

or

 

service

 

technician.

 

 

Menu Settings 

 Settings 

Configuration

 

contains:

 

 

Time

 

and

 

Date

 

 

Language

 

 

Remote

 

control

 

 

Auger

 

Calibration

 

 

Fan

 

Calibration

 

 

Summer

Winter

 

 

Automatic

 

Power

 

Settings 

 Time and Date 

Setting

 

of

 

current

 

data

 

and

 

time.

  

 

Select

 

field

 

with

 

the

 

keys

 

 

,

 

 

Confirm

 

selection

 

,

 

 

Using

 

the

 

keys

 

 

 

set

 

the

 

values

 

for:

 

hour,

 

minute,

 

day,

 

month

 

or

 

year.

 

 

Settings 

 Language 

Selection

 

of

 

language

 

for

 

the

 

messages

 

from

 

the

 

controller.

 

 

Settings 

 Remote control 

Switching

 

on

 

or

 

switching

 

off

 

the

 

control

 

by

 

remote

 

module.

 

 

Settings 

 Auger Calibration 

Calibration

 

of

 

endless

 

screw

 

allows

 

changing

 

speed

 

of

 

operation

 

or

 

duration

 

of

 

operation

 

of

 

drive

 

of

 

the

 

conveying

 

screw.

 

Factory

 

setting

 

is

 

0,

 

while

 

value

 

set

 

by

 

the

 

user

 

should

 

be

 

between

 ‐

7

 

to

 

7.

 

 

Settings 

 Fun Calibration 

Fan

 

calibration

 

is

 

intended

 

for

 

changing

 

of

 

flue

 

gas

 

fan

 

speed

 

from

 ‐

7

 

to

 

7

 

in

 

relation

 

to

 

the

 

factory

 

settings

 

(value

 

0).

 

 

Settings

 Summer-Winter 

This

 

setting

 

allows

 

selecting

 

operating

 

mode

 

of

 

the

 

hydraulic

 

system

 

depending

 

on

 

the

 

season.

 

Manual Load

ON

<<

OFF

Menu Settings
Settings
Keyboard Menu

System Menu

SET

Time and Date

17

: 22

Wednesday

18 / 09 / 2019

Language
Latviesu
Lietuviu
Magyar
Nederlandse

Polski

Remote Control

ON

<<

OFF

Auger Calibration

Max: 7
Set:

0

Min: -7

Fun Calibration

Max: 7
Set:

0

Min: -7

Содержание NG01 HYDRO

Страница 1: ...operating manual controller NG01 HYDRO with control panel K100 adapted for operation with HYDROPELL dry stoves fired with pellet translation of original operating manual issue 1 September 2019 www pl...

Страница 2: ......

Страница 3: ...ation status 7 Alarms 8 Messages 8 User menu 9 Menu Customization 9 Menu Customization Power 9 Menu Customization Thermostats 9 Menu Customization Chrono 9 Menu Settings 11 Menu Settings Settings 11 M...

Страница 4: ...nel with antistatic cover Safety notice Prior to installation user should acquire knowledge of Environmental and safety standards Follow all local regulations inclusive of these given in the national...

Страница 5: ...e increase K5 exit to information screen value decrease Diodes Designation Icon Description L1 clock current time L2 signalling of activation of chrono mode L3 signalling of empty pellet container L4...

Страница 6: ...ting system The configuration comprises of three stages Selection of hydraulic system Selection of controlled device by output V2 P44 Selection of devices connected to inputs IN2 P77 IN3 P75 IN6 P78 a...

Страница 7: ...ted to IN2 IN3 IN6 IN7 inputs Device Paramete r Inputs IN2 P77 IN3 P75 IN6 P78 IN7 P82 None input not connected 0 Door sensor 2 Pellet thermostat 3 Ambient thermostat 4 Flow switch 5 Pellet level sens...

Страница 8: ...mmunication error Er17 Air flow adjustment failed Er18 No fuel Er23 Boiler of DHW sensor opened Er25 Cleaning motor damaged Er39 Damaged sensor of flowmeter Er41 Minimum flow of air in Control Checkin...

Страница 9: ...n Thermostats This menu allows changing values of temperature of stove thermostat Boiler set value is within the determined limits between the given Max and Min values Select required value of water t...

Страница 10: ...h the keys Confirm selected value with a key Repeat operations for the other fields Each cycle can be activated or blocked pressing a button Active time interval is marked by filling a bullet precedin...

Страница 11: ...m the controller Settings Remote control Switching on or switching off the control by remote module Settings Auger Calibration Calibration of endless screw allows changing speed of operation or durati...

Страница 12: ...er device INP input KEYB Keyboard OUT output CMPS complex equipment SENS sensor COM communication link Keyboard Menu Contrast This option is used to adjust contrast of the display Keyboard Menu Min Li...

Страница 13: ...for reaching of set water temperature decreasing at the same time portions of supplied pellet Work cycle After initiation of the firing the stove switches successively to the following operation modes...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...DEFRO Sp ka z ograniczon odpowiedzialno ci Sp k 00 403 Warszawa ul Solec 24 253 Manufacturing plant Ruda Strawczy ska 103 A 26 067 Strawczyn tel 41 303 80 85 fax 41 303 91 31 biuro defro pl...

Отзывы: