8
Operation (continued)
2
Setting the sensor for testing
NOTE:
When the “Auto / Test” control is set to the “Test”
position, the light fixture will operate during the day or
night. The light will stay on for 8 seconds after all motion
is stopped.
□
Turn the “Auto / Test” control fully clockwise to
the “Test” position.
□
Turn the “TIME” control fully counterclockwise
to the minimum position.
□
Turn the “SENS” control fully clockwise to the
minimum position.
□
After all adjustments are complete, turn the
“Auto / Test” control fully counterclockwise to
the “Auto” position.
NOTE:
The motion sensor will need to completely warm
up (60 seconds) before beginning the setup process.
A
uto
Te
st
TIME
S
ENS
3
Adjusting the motion sensor
detection zone
□
Perform a “walk test”: walk in an arc across
the front of the motion sensor (C).
□
Watch the light. The light will come on and the
red LED will flash indicating motion has been
detected.
□
Stop, wait for the light to turn off, and then
begin walking again.
□
Continue this process until the detection zone
has been established.
□
If needed, gently grasp the motion sensor (C)
and move it from side to side or up and down
to adjust the detection zone.
4
Adjusting the SENS control
□
To increase the detection zone, turn the
“SENS” control counterclockwise.
□
To decrease the detection zone, turn the
“SENS” control clockwise.
NOTE:
The motion sensor (C) is more sensitive to motion
moving across the front of the sensor. The motion sensor
(C) is less sensitive to motion moving directly toward the
front of the sensor.
NOTE:
The higher the “SENS” setting (sensitivity), the
greater the possibility of false triggering. To reduce false
triggering, turn the “SENS” control clockwise.
TIME
S
ENS
C
C
C