20
5.4
Unit settings (normal operating mode)
5.4.1 Setting the desired humidity value
modify
confirm
cancel
Note: The reference humidity value can be modified only if program mode is deactivated (see chap
-
ter 5.5).
Setting range:
30...90 %rH
Factory setting:
45 %rH
Notes on setting:
The optimum reference value depends on various factors. For apartments we
recommend a value of 40 – 45 %rH.
Note: After initial commissioning or replacement of the vaporizer mat the humidification perform
-
ance of the Defensor PH28/PH28A will be slightly reduced be cause the evaporator mat takes a
few days to become fully saturated with water. Maximum performance is available after one week,
approximately.
Furthermore, the humidification performance depends on the ambient tem pe rature.
30...90 %rH
Standard operating display
(see chapter 5.4.2)
Set value
45%rH
Set value
New Value
Set value
Old Value
Set value
45%rH