- 11 -
DISPLAY CO LEVEL BUTTON (FOR MODEL CA6150):
To manually display the
current and highest CO level detected, press the
DISPLAY
CO LEVEL
button once. The
LCD will display the recorded data in the following order:
1. The current CO level detected, and
2. The highest, or peak, CO level detected from 10-999 ppm.
3. The total length of time the alarm has detected the highest CO level, within 10% of
the peak, from 0-999 minutes.
Each reading will appear for five seconds. To erase the record in memory, press the
TEST/RESET/MUTE
button when the readings are displayed. The alarm will burst a long
beep, and the display reads
.
9. TEST AND MUTE ALARM
To test the alarm, press the
TEST/RESET/MUTE
button on the cover and hold it down for
a minimum of 2 seconds or until the alarm starts beeping and
ALARM
red LED flashes,
then release. This test will simulate a CO concentration of approximately 300 ppm CO
gas. The alarm will sound 4 short beeps and LED will flash Red at the same time,
followed by a 5 second pause, and then repeat 4 more short beeps with flashing Red
LED if all of the electronic circuitry and buzzer are working correctly. The current CO
level will also be displayed for model CA6150.
To mute the audible horn during an alarm signal, press the
TEST/RESET/MUTE
button.
The
ALARM
red LED will flash 4 times, the model CA6150 will display
for 5
seconds, and the horn will be temporarily silenced. If a CO level of 70 ppm or more
continues to be detected, the audible and visual alarm signals will be automatically
reactivated within 5 minutes. See Section 10
WHAT TO DO WHEN THE ALARM
SOUNDS
.
To mute the audible horn during a low battery signal (
)
condition, press the
TEST/RESET/MUTE
button. The green LED will blink for 5 seconds, the model CA6150
will display
at the same time, and the horn will be temporarily silenced for 24 hours.
The low battery signal symbol
will be continuously shown in the CA6150 display.
When the audible signal reactivates, you can continue to mute the horn for an additional
24 hour period by again pressing the
TEST/RESET/MUTE
button. The horn can only be
turned off during the first 7 days of the low battery signal activation. After 7 days, the
alarm will return to its normal low battery signal condition; 1 chirp per minute, green LED
blinks for 5 seconds, and model CA6150 continuously displays
.
To test the alarm during a low battery signal condition, press and hold
TEST/RESET/MUTE
button for minimum 2 seconds when the audible signal is not
sounding.
To mute the audible signal during an “End-of-Life” condition, press the
TEST/RESET/MUTE
button. The
SERVICE
red LED will glow for 5 seconds, the model
CA6150 will display
at the same time, and the horn will be temporarily silenced for
60 hours. When the audible signal reactivates, you can continue to mute the horn for
an additional 60 hour period by again pressing the
TEST/RESET/MUTE
button. The horn
can only be turned off during the first 30 days of the “End-of-Life” signal activation. After