Defender 3.0 Voice Plus Скачать руководство пользователя страница 14

13

Monitor

 • 

Control

 • 

Surveillance

20

Monitor

 • 

Control

 • 

Surveillance

Zone 1

 - Enable personal respor ng

Zone 2

 - Enable CMS respor ng

Zone 1

 - Keypad buzzer on during entry delay

Zone 2

 - Keypad buzzer on during exit delay

Zone 4

 - DTMF dialing

Zone 5

 - Arm using H or A

Zone 6

 - Panic bu on P

Zone 7

 - Remote control

Zone 8

 - Bell squawk

Enable personal respor

Ɵ

ng

On - The panel will report the event to the user
O

 - The panel will not report the event to the user

Enable CMS respor

Ɵ

ng

On - The panel will communicate with the CMS centre
O

 - The panel will not communicate with the CMS centre

Enable Fix line

On - The panel will communicate with mobile phone
O

 - The panel will not communicate with mobile phone

Enable ba

Ʃ

ery low warning on keypad

On - The keypad will generate tone when the ba ery low
O

 - The keypad will not generate tone when the ba ery low

Keypad buzzer on during entry delay

On - The keypad will produce the entry tones

O

 - Entry tones will not produce

Keypad buzzer on during exit delay

On - The keypad will produce the exit tone

O

 - Exit tone will not produce

DTMF dialing

On - The panel will dial using DTMF format

O

 - The panel will dial using older pulse format

Arm using H or A

On - Enable arm using H or A key

O

 - Disable arm using H or A key

Bu

Ʃ

on P

On - Enable using bu on P for panic bu on

O

 - Disable using panic bu on

Remote Control

On - The panel will Enable remote control

O

 - Disable remote control

Bell Squawk

On - The panel siren will pulsed once_when the 

system is arm, pulsed twice when the system is 

disarm

O

 - The siren will behaves normally on arm and 

disarm

Zone 4

 - Enable Fix line

Zone 8

 - Enable ba ery low warning on keypad

Communicator

Se

ƫ

ng

Address

Zone 1

Zone 2

Zone 3

Zone 4

Zone 5

Zone 6

Zone 7

Zone 8

31

System
Op

Ɵ

on

Address

Zone 1

Zone 2

Zone 3

Zone 4

Zone 5

Zone 6

Zone 7

Zone 8

33

Technical Data

g. Refer to 

fi

gure 4.0

• Status – to show the status for each zone in condi on Arm, Trigger, Ready, Open and Bypass.
• Last Trigger – to show which zone was triggered a er disarm.
• Camera Link – IP camera link for each zone
• Bypass - to set or clear the zone bypass

Figure 4.0 Home alarm panel status

ZONE

STATUS

BYPASS

LAST

TRIGGER

CAMERA

LINK

Zone 1

Garden

Dining

Kitchen

Fence

Corridor

Hall

Front Door

Back Door

Zone 2

Zone 3

Zone 4

Zone 5

Zone 6

Zone 7

Zone 8

Ready

Ready

Ready

Ready

Ready

Ready

Ready

Ready

Camera

Link

Camera

Link

Camera

Link

Camera

Link

Camera

Link

Camera

Link

Camera

Link

Camera

Link

Arm the alarm

Configuration
DSA

Disarm the alarm

On/Off the light

If PGM are 104,
105, 106, 107 
cannot turn on/off
manually. Refer
to Installer
manual for PGM
definition

Содержание 3.0 Voice Plus

Страница 1: ...Voice Plus SpecificaƟons are subject to change without noƟce Defender is a registered trademark of defender Co Ltd Other brands and product names are trademarks of their respecƟve holders Copyright 2009 All rights reserved Defender Co Ltd ...

Страница 2: ...tructions in the literature accompanying the appliance INFORMATION This equipment has been tested and found to comply with limits of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated WARNING Do not changes or modify any parts or component used and approved by the manufacturer WARNING To prevent electric shock and ri...

Страница 3: ...m to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmentally safe recy...

Страница 4: ...sing in high temperature condi ons PrecauƟons Do not install system under extreme temperatme condi ons or in high humidity environment DescripƟon Zone 1 2 3 4 5 6 7 8 Entrance Internal Delay Instant 24 hour Timer Entry Time Exit Time Bell Cut Off Time Telephone Number of ring before answer Each number well be dial 1 2 3 4 System InstallaƟon InformaƟon ...

Страница 5: ...ge due to causes beyond the control such as excessive voltage mechanical shock or water damage damage caused by unauthorized aƩachment alteraƟons modificaƟons or foreign objects damage caused by peripherals defects caused by failure to provide a suitable installaƟon environment for the products damage caused by use of the products for purposes other that those for which it was designed InternaƟona...

Страница 6: ...d this manual carefully and have you installer instruct you on system operaƟon and on which features have been implemented in your system About Your Security System WARNING Remember The system requires minimum maintenance This system is an advanced security system it does not offer guaranteed protection against burglary fire or other emergency Whether commercial or residential Intruders may gain a...

Страница 7: ...ystem programming menu Press 40 Enter the entry Ɵmer Press to save exit programming menu To Set The Exit Time Press o follow by installer code to access the system programming menu Press 42 Enter the exit Ɵmer Press to save exit programming menu To Set The Silent Zone Press o follow by installer code to access the system programming menu Press 16 Enter the zone number Press 2 Ɵme to save exit prog...

Страница 8: ...xxxx xxxx 4 digit To Add The Phone Number The system must be disarm Press 7 follow by master code 4 digit Press user number x maximum can set up to 4 user Press the user phone number Press a er finish to save exit Programming menu To Delete The Phone Number Press 7 follow by master code 4 digit Press user number x which want to delete Press to save exit Programming menu To Turn On Off The Chime Mod...

Страница 9: ...is no assign by Router example refer to figure 10 3 192 168 1 3 was assign by Router if user want to use another IP address as staƟc 192 168 1 10 Go to Network ConfiguraƟon figure 10 0 un Ɵck the ENABLE DHCP and change the IP Address to 192 168 1 10 and click the Save Config buƩon Reboot message will shown figure 10 1 PS Exit close the browser without click the link hƩp DEFENDER 8088 Login to Rout...

Страница 10: ...re 10 2 PS Please do not click the link first hƩp DEFENDER 8088 Figure 10 1 Reboot Login to Router s configuraƟon select DSA Mac address and IP address and change the status to staƟc Then click save the new configuraƟon info was shown in figure 10 3 This page allows the configuration of the board s network settings CAUTION Incorrect settings may cause the board to lose network connectivity Recover...

Страница 11: ...igure 9 0 Reload buƩon for reload the latest informaƟon Maximum show 80 events aŌer 80 events the next events will show at first locaƟon Figure 9 0 Log Status Date Time 11 10 2010 10 19 11 10 2010 10 19 11 10 2010 10 19 11 10 2010 10 19 11 10 2010 10 19 11 10 2010 10 19 11 10 2010 10 09 11 10 2010 10 09 11 10 2010 10 09 11 10 2010 10 09 11 10 2010 10 01 11 10 2010 09 25 11 10 2010 09 21 11 10 2010...

Страница 12: ...user ParƟƟon 2 user is default seƫng connect to zone 8 b PGM seƫng figure 6 0 Timer Arm Disarm set the auto mer arm or disarm the par on 1 or par on 2 alarm panel 24 hour format Timer PGM set the auto mer on or off light 24 hour format If PGM are not 64 65 and 66 cannot auto mer func on Refer to installer manual for PGM defini on c Network seƫng figure 7 0 For Dynamic DHCP ck the Enable DHCP For St...

Страница 13: ...el will report Arm Disarm to the centre Off The panel will not report Arm Disarm to the centre Report AC Fail On The panel will report AC Fail to the centre Off The panel will not report AC Fail to the centre Report Enter Exit Programming Mode On The panel will report Enter Exit programming to the centre Off The panel will not report Enter Exit programming to the centre Report Telephone Line Fault On...

Страница 14: ...arm using H or A key Off Disable arm using H or A key BuƩon P On Enable using bu on P for panic bu on Off Disable using panic bu on Remote Control On The panel will Enable remote control Off Disable remote control Bell Squawk On The panel siren will pulsed once_when the system is arm pulsed twice when the system is disarm Off The siren will behaves normally on arm and disarm Zone 4 Enable Fix line Zon...

Страница 15: ... auto hang up during personal repor ng Communicator dial loop Number of me to dial on each telephone number Answer ring Number of ring required in order to answer the incoming call Can be set from 000 to 255 ring Communicator password error auto hang up Number of error password digit is allowed to key in before communicator auto hang up CMS periodic report This mer controls the interval me of the ...

Страница 16: ...Code Reset panel Address 70 71 72 73 76 98 99 1397 0000 0000 Default Value System System Time System Date System Year Auto Arm Par on 1 Auto Disarm Par on 1 Auto Arm Par on 2 Auto Disarm Par on 2 Night Mode begin me Night Mode end me Control Timer 1 on Control Timer 2 on Control Timer 1 off Control Timer 2 off Auto Off mer Address 30 31 32 33 34 35 36 37 38 43 Minute 42 41 40 39 HHMM HHMM HHMM HHMM H...

Страница 17: ...Open Without Auto Off Feature Zone Open With Auto Off Feature Control follow Timer 1 Zone Open with Auto Off Feature during Night Mode Zone Open without Auto Off Feature during Night Mode Control follow Timer 2 Control follow Timer 1 2 Ac vate during away arm without auto off feature Ac vate during away arm with auto off feature Ac vate during away arm with auto off feature during Night Mode Ac vate duri...

Отзывы: