Delay
- The zone will not cause an alarm during the entry / exit delay me.
Internal
- The zone will not cause an alarm during home arm mode.
Instant
- The zone will cause an instant alarm when the system is arm.
24 Hour
- The zone will ac vate all alarm immediately triggered regardless of system arm / disarm.
Fire
- The zone will cause a unique alarm with dis nc ve ‘
fi
re’ tone if it is violated regardless the system is arm or
disarm.
Silent
- The siren will not trigger when the zone open.
Zone respond
- Have 2 di
ff
erent respond me: ‘on’ mean slow respond, ‘o
ff
’ mean fast respond.
Intelligent zone 1 & 2
- The zone will not trigger siren before the zone counter and zone reset mer expires.
Zone par
ƟƟ
on 1 & 2
- Par
on allow the system to be divided into areas of protec on so that di
ff
erent par
on can be
arm and disarm independently from each other.
Auto reset zone
- The zone will restore become normal a er the bell me.
Par
ƟƟ
on 1 & 2 user
- To assign the user to access the par
on.
(Default: All user only can access to par
ƟƟ
on 1 only)
Zone 1
- Report Panic
Zone 2
- Report Duress
Zone 3
- Report Arm / Disarm
Zone 4
- Report AC Fail
Report Panic
On - The panel will report panic to the centre
O
ff
- The panel will not report panic to the centre
Report Duress
On - The panel will report Duress to the centre
O
ff
- The panel will not report Duress to the centre
Report Arm / Disarm
On - The panel will report Arm / Disarm to the centre
O
ff
- The panel will not report Arm / Disarm to the centre
Report AC Fail
On - The panel will report AC Fail to the centre
O
ff
- The panel will not report AC Fail to the centre
Report Enter / Exit Programming Mode
On - The panel will report Enter / Exit programming to the centre
O
ff
- The panel will not report Enter / Exit programming to the centre
Report Telephone Line Fault
On - The panel will report telephone line fault to the centre
o
ff
- The panel will not report telephone line fault to the centre
Report Bypass
On - The panel will report Bypass to the centre
O
ff
- The panel will not report bypass to the centre
Report Ba
Ʃ
ery low
On - The panel will report ba ery low to the centre
O
ff
- The panel will not report ba ery low to the centre
SYSTEM SETTING
CMS
Repor
Ɵ
ng
Address
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
Zone 8
30
Technical Data
Technical Data
Zone 5
- Report enter / exit programming mode
Zone 6
- Report Telephone line fault
Zone 7
- Report Bypass
Zone 8
- Report Ba ery low
3.0 Con
fi
gura
Ɵ
on DSA
a. Zone se
ƫ
ng (
fi
gure 5.0)
• Loca on – loca on name for each zone (max 10 characters).
• Camera Link – IP camera web link for each zone (max 40 characters).
Figure 5.0 Zone se
ƫ
ng
ZONE
ZONE 1
ZONE 2
ZONE 3
ZONE 4
ZONE 5
ZONE 7
ZONE 6
ZONE 8
LOCATION
Garden
Dining
Kitchen
Fence
Corridor
Hall
Front Door
Back Door
http://www.zonelink1.com.my
http://www.zonelink2.com.my
http://www.zonelink3.com.my
http://www.zonelink4.com.my
http://www.zonelink5.com.my
http://www.zonelink6.com.my
http://www.zonelink7.com.my
http://www.zonelink8.com.my
CAMERA LINK
LIGHT ZONE
LOCATION
ZONE 1
ZONE 2
Inside
Outside