TROUBLESHOOTING
No picture after connecting to the recorder and power supply.

• 

Check the power supply is suitable and connected correctly and that the 

network cable is correct and installed properly.

The picture has flowing interference ripples or generally poor.

• 

May be caused by fluctuations in the AC mains power supply.

 

Check the monitor and peripheral equipment used to determine if the 

problem is with the camera feed or another component in the network.

• 

Ensure the power supply is stable and of sufficient power and all 

connections are clean with low impedance.

The picture colour changes continuously 

• 

Installation close to fluorescent lighting can cause this. Try to keep a 

reasonable distance from the fluorescent fitting.

• 

Interference from an electromagnetic source close to the camera or the 

supply wiring.

Gamma Characteristic

• 

Camera Gamma characteristic is 0.45.

Scanning Mode

• 

NTSC or PAL mode.

FEATURES

• 

The camera connection cable has a menu control button under a small 

round plastic cover on the splitter.

• 

When the camera is operating, pressing the button will display an on 

screen menu for setting further options:-

1.  AE

 - brightness and exposure 

2.  AWB

 - white balance adjustment 

3.  Day/Night 

- gain control

4.  Image Enhance 

- adjusts contrast, saturation and sharpness

5.  Video Setting

 - HD/SD

6.  Language

 - set your language preference for the menu

7.  Function

 - set privacy and motion detection zones

8.  Version

 - displays the firmware version of the camera

9.  Reset 

- reset to defaults

10. Save and Exit

 - saves all amended settings and exits the menu

11.  Exit

 - quits without saving

• 

The button acts like a joystick so you can switch between options or make 

changes to the settings.

• 

The options available may differ slightly depending on the camera model.