Lock/Unlock pattern
– to create pulse(s) when the alarm changes from armed
to disarmed and from disarmed to armed if DEFA remote is used.
Arming pulse
– a pulse which is triggered each time the arming signal is received.
Disarming pulse
– a pulse which is triggered each time the disarming signal is
received.
Armed status
– active signal when the alarm is armed.
Disarmed status
– active signal when the alarm is disarmed.
These functions can have individual settings to control timing etc.
Starter Kill (P1)
In some countries this connection is mandatory. Contact your local reseller for information.
Cut the wire from the ignition lock to the starter solenoid. Connect the Red/Blk (pin 2) wire to
the ignition lock side of the wire and then Wht/Grn (pin 4) wire to the solenoid side. This relay
can be controlled to act as either Starter Kill or Immobillizer.
The Starter Kill function disables the connection between the two cables when the alarm is
armed and connects them when the alarm disarms.
The immobilizer function disables the connection between the cables a predefined time after
the ignition is turned off. If no door on the veichle is opened the connection between the cables
will be enabled as soon as the ignition is turned on again, but if a door is opened the alarm has
to receive a disarm signal to enable the connection again.
USB (P8)
This connection is only used when programming the alarm unit with the specific car or peripheral
settings. Read the instructions that accompanied the DEFA Express system.
Peripherals on the LIN bus
All peripherals are connected to the alarm unit on the LIN bus (P6 & P7). If more than two
devices are to be connected, a DEFA LIN splitter can be used.
The devices on the LIN bus are automatically paired with the alarm upon first power up of the
alarm unit and stored in the alarm unit’s LIN device table.*
If the device table has to be erased and a resynchronization has to be done, do as follows:
1. Connect all units to the LIN bus
2. Disarm the alarm.
3. Turn the ignition on.
4. Press the window module button for 10 seconds.
5. The alarm unit confirms erased table and resynchronization with flashing LED.
6. Turn the ignition off.
* If new peripherals are connected to an already paired LIN bus, or if the settings for a device
on the bus is changed using DEFA Express, a new synchronization has to be done.