Deep-SeaLite®
User
Manual
6/19/02
6
are clean. If there is no apparently damaged O-ring, remove the glass dome and inspect the edge
of the glass. If the edge is chipped, this is probably the source of the leak, and the dome should
be replaced.
If a light is flooded and/or damaged, we recommend that the light be returned to DeepSea Power
& Light for repair or replacement; DeepSea Power & Light cannot be responsible for any
damage incurred during emergency field repairs. Such repairs should be undertaken only as a
last resort and by qualified personnel. Spares kits are available from DeepSea Power & Light.
8. General
Notes
Do not burn a Deep-SeaLite® out of water for more than about 30 seconds.
Do not operate any high voltage electrical equipment without using a Ground Fault Interrupt
circuit for safety, especially when divers are in the water!
Do not operate a lamp at higher than recommended voltage. The lamp filament will melt with
severe over-voltage, and slight over-voltage drastically reduces lamp life.
Be sure that any fingerprints are cleaned off the lamp with isopropyl alcohol before use.