FRONT PANEL EDITOR PARAMETERS
Section
Parameter As Shown On Display
Value
Display
Contrast
0 %
Backlight Level
0 %
Language
English
Current Date and Time
Day:month:year,
hour:minute:seconds
Engine
Oil Pressure Low Shutdown
(W hen Enabled)
0.00 bar, kPa, psi
Oil Pressure Low Pre Alarm
(W hen Enabled)
0.00 bar, kPa, psi
Coolant Temperature High Pre Alarm (When
Enabled)
0 ºC, ºF
Coolant Temp High Controlled Shutdown
(W hen Enabled)
0 ºC, ºF
Coolant Temperature High Shutdown (When
Enabled)
0 ºC, ºF
Start Delay Off Load
0 h 0 m 0 s
Start Delay On Load
0 h 0 m 0 s
Start Delay Telemetry
0 h 0 m 0 s
Pre Heat Temperature (When Enabled)
0 ºC, ºF
Pre Heat Timer
0 h 0 m 0 s
Post Heat Temperature (When Enabled)
0 ºC, ºF
Post Heat Timer
0 h 0 m 0 s
Cranking
0 m 0 s
Crank Rest
0 m 0 s
Safety On Delay
0 m 0 s
Smoke Limiting
0 m 0 s
Smoke Limiting Off
0 m 0 s
Warming
0 m 0 s
Cool Down Time
0 h 0 m 0 s
Under Speed Shutdown
Active / Inactive
Under Speed Shutdown
(W hen Enabled)
0 rpm
Under Speed Warning
Active / Inactive
Under Speed Warning (When Enabled)
0 rpm
Over Speed W arning
Active / Inactive
Over Speed W arning (When Enabled)
0 rpm
Over Speed Shutdown
0 rpm
Speed Overshoot Delay
0 m 0 s
Speed Overshoot
0 %
Fail To Stop Delay
0 m 0 s
Battery Under Voltage Warning
Active / Inactive
Battery Under Voltage Warning Delay (W hen
Enabled)
0 h 0 m 0 s
Battery Under Voltage Warning
0 V
Battery Over Voltage Warning
Active / Inactive
Battery Over Voltage Warning Delay (W hen
Enabled)
0 h 0 m 0 s
Battery Over Voltage Warning
0 V
Charge Alternator Failure Warning
Active, Inactive
Charge Alternator Warning Delay
(W hen Enabled)
0 h 0 m 0 s
Charge Alternator Failure Warning
0.0 V
Charge Alternator Failure Shutdown
Active / Inactive
Charge Alternator Shutdown Delay
(W hen Enabled)
0 h 0 m 0 s
Charge Alternator Failure Shutdown
(W hen Enabled)
0.0 V
Priming Delay
0 s
Clutch Engage Speed
0 rpm
Clutch Disengage Speed
0 rpm
Idle Speed
0 rpm
Warming Speed
0 rpm
Cooldown Speed
0 rpm
Starting
0 rpm
Priming Speed
0 rpm
Min Speed
0 rpm
Default Speed
0 rpm
Max Speed
0 rpm
Reset Default Speed on Start-up
Active / Inactive
Cooling at Idle
0 h 0 m 0 s
FRONT PANEL EDITOR PARAMETERS (CONTINUED)
Section
Parameter As Shown On Display
Value
Engine
Delayed Engine Start
0 h 0 m 0 s
(continued)
Delayed Engine Stop
0 h 0 m 0 s
Engine Speed Transient Delay
0.0 s
Selectable Speed Transfer Time
0 m 0.0 s
Timers
LCD Page Timer
0 h 0 m 0 s
Scroll Delay
0 h 0 m 0 s
Engine Pre Heat Timer (When Enabled)
0 m 0 s
Engine Cranking
0 m 0 s
Cranking Rest
0 m 0 s
Safety On Delay
0 m 0 s
Smoke Limiting
0 m 0 s
Smoke Limiting Off
0 m 0 s
Engine Warming
0 h 0 m 0 s
Engine Cooling
0 h 0 m 0 s
Engine Overspeed Overshoot
0 m 0 s
Engine Fail To Stop Delay
0 m 0 s
Battery Under Voltage Warning Delay
0 h 0 m 0 s
Battery Over Voltage Warning Delay
0 h 0 m 0 s
Return Delay
0 h 0 m 0 s
DPF Ramp*
0 s
Schedule
Schedule
Active / Inactive
Schedule Bank Period
Weekly / Monthly
On Load / Off Load / Auto Start Inhibit, Week,
Start Time, Run Time and Day
Selection (1-8)
Press
to begin
editing then up or down
when selecting the
different parameters.
Active
Main Configuration
Press
to begin
editing then up or down
when selecting the
different configurations
Config
Alternative Config 1
Select
Alternative Config 2
Alternative Config 3
Alternative Config 4
*Electronic Engines Only
FIXING CLIPS
NOTE: In conditions of excessive vibration, mount the module on suitable
anti-vibration mountings.
The module is held into the panel fascia using the supplied fixing clips.
•
Withdraw the fixing clip screw (turn anticlockwise) until only the pointed
end is protruding from the clip.
•
Insert the three ‘prongs’ of the fixing clip into the slots in the side of the
module case.
•
Pull the fixing clip backwards (towards the back of the module) ensuring all
three prongs of the clip are inside their allotted slots.
•
Turn the fixing clip screws clockwise until they make contact with the panel
fascia.
•
Turn the screws a little more to secure the module into the panel fascia.
Care should be taken not to over tighten the fixing clip screws
ACCESSING THE ‘RUNNING’ CONFIGURATION EDITOR
•
The ‘running’ editor can be entered while the engine is running. All protections
remain active if the engine is running while the running editor is entered.
•
Press and hold the
(Tick) button to enter the running editor.
RUNNING CONFIGURATION EDITOR PARAMETERS
Section
Parameter As Shown On Display
Values
Display
Contrast
0 %
Backlight Level
0 %
Dual Mutual
Language
English
Engine
DPF Auto Regen Inhibit
Active / Inactive
DPF Manual Regen
Active / Inactive
DPF Manual Regen Cancel
Active / Inactive
DIMENSIONS AND MOUNTING
DIMENSIONS
240.0 mm x 181.1 mm x 42. mm
(9.4” x 7.1” x 1.6”)
WEIGHT
0.7 kg
(1.4 Ib)
PANEL CUTOUT
220 mm x 160 mm (8.7” x 6.3”)
TEMPERATURE
Operating:
-40 ºC to +70 ºC
(-40 ºF to +158 ºF)
Storage:
-40 ºC to +80 ºC
(-40 ºF to +176 ºF)
REQUIREMENTS FOR UL CERTIFICATION
WARNING!: More than one live circuit exists, see diagram overleaf for further information.
Specification
Description
Screw Terminal Tightening Torque
•
4.5 lb-in (0.5 Nm)
Conductors
•
Terminals suitable for connection of conductor size 13 AWG to 20 AWG (0.5 mm² to 2.5 mm²).
•
Conductor protection must be provided in accordance with NFPA 70, Article 240
•
Low voltage circuits (35 V or less) must be supplied from the engine starting battery or an isolated secondary circuit.
Current Inputs
•
Must be connected through UL Listed or Recognized isolating current transformers with the secondary rating of 5 A max.
Communication Circuits
•
Must be connected to communication circuits of UL Listed equipment
DC Output Pilot Duty
•
0.5 A
Mounting
•
Suitable for flat surface mounting in Type 1 Enclosure Type rating with surrounding air temperature -22 ºF to +122 ºF (-30 ºC to +50 ºC)
•
Suitable for pollution degree 3 environments.