background image

Dedrone 

4  Set Up 

IM-Inst-EK2536en 

 

15 

4.5

 

Set Up with LAN Connection 

For this setup the Tec Case is not required. Instead of the Tec Case, you need a network access 
for your DroneTracker and PC as well as the capability, to find out the IP address of the 
DroneTracker in that network. 

Requirements: 

 

Plug socket for power supply 

 

LAN access for your Sensors 

 

Network access via Wi-Fi or LAN for your Laptop 

Procedure: 

 

Multi Sensor or RF-100 breaks 

By overheating of the Tec Case, the Tec Case shuts down automatically and the sensor could 
break. 

 

Take care, that inside the Tec Case the temperature is not getting over 149 °F (65 °C), for 
example by open the lid or providing shadow. 

 

1

 

Turn on your notebook, set up the tripod, screw the tripod head on the tripod and 
attach the Dedrone sensors to the tripods. 

 

 

2

 

If you set up the RF-100, screw the antenna on 
the screw threads at the top of the RF-100. 
Therefor note the correct positioning of the 
short and long antenna. 

 

 

 

3

 

Turn on the main switch inside the Tec Case. 

 

The battery display shows the charge state: 

o

 

Green: Ready/standby 

o

 

Orange

: low state of charge, full 

functionality is not guaranteed, 

charge 

the battery

 (see chapter 5, page 17) 

o

 

Red: Battery is empty, shut down in next 
seconds. 

 

 

 

4

 

Use the switch outside the Tec Case, to turn the power on. 
Wait for 

30 seconds

, before following the next steps. 

 

The router boots and is going to provide the Wi-Fi network and is preparing LAN 
communication. 

short 

long 

Содержание DroneTracker Event Kit 2.5

Страница 1: ...IM Inst EK2536en ENGLISH INSTALLATION Manual DroneTracker Event Kit 2 5 ...

Страница 2: ...mbH Internal reproduction used solely for the purpose of product evaluation or other proper use is allowed and does not require prior approval Copyright This manual is the intellectual property of Dedrone GmbH and is protected by copyright All rights reserved Dedrone GmbH Miramstraße 87 34123 Kassel Germany Fon 49 561 861799 0 Fax 49 561 861799 111 Email info dedrone com 2017 Dedrone GmbH All righ...

Страница 3: ...the RF 100 10 4 2 Choose Position of the Multi Sensor 11 4 3 Set Up autonomously 12 4 4 Cable Requirements and Preparation Crimp 14 4 5 Set Up with LAN Connection 15 5 Charge Tec Case 17 6 Shut Down Sensor and Tec Case 18 7 Update 19 7 1 Update a Dedrone Sensor with the Tec Case 19 7 2 Update DroneDNA with the Tec Case 20 8 Troubleshooting 21 8 1 Tec Case is beeping 21 8 2 Single Components don t ...

Страница 4: ...d RF 100 is intended for civil commercial and private use The Multi Sensor is not a security camera to observe the ground The product is suitable for outdoor use Use this product only in accordance with the information provided in the enclosed documentation and with the locally applicable legal standards and directives Any other application may cause personal injury or property damage Do not use t...

Страница 5: ...yourself Refer all servicing to qualified service personnel This device has no user serviceable internal parts Whenever any damage to the device has occurred unplug the devices from the power source and refer servicing to qualified service personnel Such damages can be the patch cable is damaged the device has been dropped or its enclosure has been damaged the device does not operate normally when...

Страница 6: ...or and RF 100 and the integrated router The Event Kit is an accessories for a mobile temporary use of a Multi Sensor and RF 100 e g at events or a product demonstration Parts of the Tec Case A Battery Charger D PC Connection B Uplink DSL Router E Power Button C PoE Connection for Sensors The router builds a network which is the interface between the Sensors and the PC or tablet This network could ...

Страница 7: ...ecodes targeted radio signals and sends the data along with an alert to the DroneTracker System Parts of the RF 100 A Power Button D RF Mounting Plate B RF 100 E Network Socket C Antenna It scans a wide frequency band for radio frequencies classifies and decodes them Thus drones with cameras for example that send video signals in real time to a ground station are identified The decoded data is rec...

Страница 8: ...ulti Sensor A Audio Sensor D Near Infrared HD Camera B Multi Sensor E DT Mounting Plate C HD Camera F DT Heat Sink With the interacting sensors the Multi Sensor is able to detect all kinds of civil drones Based on multiple parameters such as noise shape and movement patterns the detection rate is optimal Depending on the environmental weather conditions drone type and drone size the detection rate...

Страница 9: ...ipods The Tripod is a mobile mount for the Multi Sensor and RF 100 The Tripods helps to exhibit and position the Multi Sensor and RF 100 3 Scope of Delivery Verify that all the parts listed in the scope of delivery are included If any items are missing notify your Dedrone Partner Do not use this product if any component appears to be damaged Please contact Dedrone in the event of damaged goods 1x ...

Страница 10: ...and mounting position for the device Ideally this is a location where the device cannot be interfered with either intentionally or accidentally Ensure that the location has the appropriate clearance from power and lightning conductors in accordance with NEC725 and NEC800 CEC Rule 16 224 and CEC Section 60 Do not install the device near the following object Any excessive heat sources Any overhead p...

Страница 11: ...est result Sonic and ultrasonic noise can disturb or disable the acoustic detection Position the Multi Sensor as far away as possible from any source of noise e g Fans Radiators Converters Speakers Electrical motors Capping power supplies Trees moving leaves producing ultrasonic noise Don t walk in front of the Multi Sensor because of that the camera could detect wrong moving objects and eventuall...

Страница 12: ...s to the tripods 2 If you set up the RF 100 screw the antenna on the screw threads at the top of the RF 100 Therefor note the correct positioning of the short and long antenna 3 Turn on the main switch inside the Tec Case and check the charge of battery at the battery display The battery display shows the charge of battery o Green ready standby o Orange low state of charge full functionality is no...

Страница 13: ...t with a patch cable c To connect your laptop by Wi Fi connect the laptop to the Wi Fi Dedrone Demo or Dedrone Demo 5GHz Password Dedrone Demo Tip For a most solid connection we recommend the LAN connection If a Wi Fi connection is needed the 5GHz Wi Fi is recommended for a more solid connection 6 Start your browser For optimal use we recommend Chrome or Firefox 7 Enter the IP 10 42 87 102 or 192 ...

Страница 14: ...ve the cable jacket carefully Therefore take care not to damage the braid and foil 4 Fold back the braid and foil over the cable jacket Note 25 mm 1 of free conductors are needed 5 Unravel the conductors sort the conductors in the required wiring standard 568 A or 568 B and push the conductors all the way in the plug The required wiring standard can be checked on the previous cut off RJ45 plug Pos...

Страница 15: ...C for example by open the lid or providing shadow 1 Turn on your notebook set up the tripod screw the tripod head on the tripod and attach the Dedrone sensors to the tripods 2 If you set up the RF 100 screw the antenna on the screw threads at the top of the RF 100 Therefor note the correct positioning of the short and long antenna 3 Turn on the main switch inside the Tec Case The battery display s...

Страница 16: ... 5GHz Password Dedrone Demo Tip For a most solid connection we recommend the LAN connection If a Wi Fi connection is needed the 5GHz Wi Fi is recommended for a more solid connection d Connect the network socket to the socket at the Event Kit For an environmentally sealed connection use a patch cable not included with the environmentally sealed connector see 4 4 Cable Requirements and Preparation C...

Страница 17: ... If possible shut down sensors and Tec Case see 6 Shut Down Sensor and Tec Case page 18 2 Connect the battery charger to the socket and tighten the screw 3 Connect the battery charger to the power supply 4 Check that the main switch inside the Tec Case illuminates blue The LED at the charger shows the charging state Orange boost charge battery level 90 Yellow top up charge battery level 90 100 Gre...

Страница 18: ...se menu OPTIONS Site Configuration 3 For each connected Multi Sensor and RF 100 right click on the sensor symbol and choose System Shutdown Hardware In the header the message Network error reconnecting is shown The light of the blue button at the Multi Sensor or RF 100 turns off 4 Push the blue button at the outside of the Tec Case The light of the blue button at the Tec Case turns off and the Tec...

Страница 19: ...cess the Multi Sensor gets destroyed Update the Multi Sensor only with a fully charged battery or connected battery charger 1 Set up the Event Kit see 4 3 Set Up autonomously page 12 or 4 5 Set Up with LAN Connection page 15 and connect to the DT Control Center 2 Choose menu OPTIONS Software Version 3 Choose Check for Updates The window Software Update appears where you can download the newest ver...

Страница 20: ...Cable Requirements and Preparation Crimp page 14 Procedure Multi Sensor destroyed by losing power supply during update The update process must be passed without any power interruptions In case of power lost during the process the Multi Sensor gets destroyed Update the Multi Sensor only with a fully charged battery or connected battery charger 1 Set up the Event Kit see 4 3 Set Up autonomously page...

Страница 21: ...hes off Cool down the inside of the Tec Case for example by open the lid or providing shadow The beeping stops when the temperature gets under 149 F 65 C 8 2 Single Components don t work Each component is protected by a single fuse In case of a short circuit or an overload the fuse could trip This could cause by Water Damaged cable Wrong connected device max 24 W typ at PoE Check and change the tr...

Страница 22: ...F 20 C to 40 C Battery Type Rugged lead acid battery 36 Ah no dangerous goods Battery Operating Time Up to 12 hours with 2 PoE units Battery Charging Time Approx 5 5 hours Power Supply Active PoE IEEE802 3at Connections Battery charging connection Router ADSL UP connector PoE connector 1 PoE connector 2 PC Notebook connector Wi Fi 2 4 GHz and 5 0 GHz Switches Start Button outside the case Transpor...

Страница 23: ... 8 250 mm Operating Temperature 4 F to 122 F 20 C to 50 C Weight 6 8 lb 3 1 kg Ingress Protection Rating IP64 Connectivity Fast Ethernet 100 Mbit s Power Supply Active PoE 802 3at Power Consumption 15 W typ Range 3 280 ft 1 km in good conditions up to 1 24 mi 2 km Radio Frequency Omnidirectional passive detecting and classification ...

Страница 24: ...Rating IP54 Range Up to 1 640 ft 500 m Internal Memory 256 GB Connectivity Fast Ethernet 100 Mbit s Power Supply Active PoE 802 3at Power Consumption 20 W typ Audio Stereo Audio Audible Sonic Ultrasonic Spectrum 0 96 kHz Video 1080p HD Camera 11 22 5 60 or 85 Infrared Near Infrared HD Camera Wi Fi Omnidirectional Scanning 2 4 GHz ISM band Mounting with Back Plate VESA 75 VESA 100 48x60 130x130 opt...

Страница 25: ...DRONE DETECTION TECHNOLOGY Dedrone GmbH 49 561 861799 0 Miramstraße 87 info dedrone com 34123 Kassel www dedrone com ...

Отзывы: