III
The value of the mathematical expression (Q
aux
· 2,5)/(220 · Q
ref
),
expressed in %, where Q
aux
is taken from the product fiche of the
solar device and Q
ref
from Regulation EU 812/2013, Annex VII Ta
ble 3 for the declared load profile M, L, XL or XXL.
6.5
Product fiche - Heat pump water heaters
Tab.17 Product fiche for heat pump water heaters
Brand name - Product name
Unit
TWH Split WH
150 E
TWH Split WH
200 E
Declared load profile
–
LL
LL
Water heating energy efficiency class under average climate conditions
–
A
A
Water heating energy efficiency under average climate conditions
%
L140.00
L125.00
Annual energy consumption
kWh
(1)
GJ
(2)
L733
L818
Other load profiles for which the water heater is suitable to use and the
corresponding water heating energy efficiency and annual electricity con
sumption
(3)
-
–
–
Thermostat temperature setting
°C
55.00
55.00
Sound power level L
WA
indoors
(1)
dB
15
15
Ability to function during off-peak hours
(1)
–
No
No
Enabled smart control settings
(4)
–
No
No
Water heating energy efficiency, under colder - warmer climate conditions %
90.00 - 154.00
85.00 - 144.00
Annual energy consumption, under colder - warmer climate conditions
kWh
(1)
GJ
(1)
1141 - 661
1210 - 710
Sound power level L
WA
outdoors
dB
59
59
(1) Electricity
(2) Fuel
(3) If applicable.
(4) If smart control settings value is "1", the water heating energy efficiency and annual electricity and fuel consumption only relate to ena
bled smart control settings
See
For specific precautions concerning assembling, installing and
maintaining: Safety, page 4
6 Appendix
7647125 - v03 - 11092017
TWH Split WH
21