1
Primary inlet
2
Domestic hot water outlet
3
Domestic cold water inlet
4
Primary outlet
CAUTION
Connect the hoses, taking care to interpose the gaskets.
1. Connect the primary inlet
1
on the tank to the tank flow on the
boiler using the hose.
2. Connect the primary outlet
4
on the tank to the tank return on the
boiler using the hose.
3. Open the manual air vent on the outlet
4
.
4. Close the return tap of the mounting frame.
5. Fill the calorifier slowly through the disconnector.
6. Close the manual air vent when water is coming out.
7. Open the return tap of the mounting frame.
¼
Refer to the installation and maintenance instructions of the
boiler.
CAUTION
Connect the hoses, taking care to interpose the gaskets.
n
DHW tank combined with a MSL boiler
Use the HX32 connecting kit to connect the DHW tank to the boiler.
1
Primary inlet
2
Domestic hot water outlet
3
Domestic cold water inlet
4
Primary outlet
CAUTION
Connect the hoses, taking care to interpose the gaskets.
C
0
0
4
0
4
9
-B
C
0
0
4
7
6
0
-A
SR130
4. Installation
26/03/2014 - 300009755-001-03