background image

ADVANCE

S U S T A I N A B L E   C O M F O R T ®

MW

-2

0

0

0

8

8

0

-2

en

User Guide

control box equipped with a DIEMATIC Evolution

for C140 boiler

LN1GBQ41 – C140 – 45

LN1GBQ62 – C140 – 65

LN1GBQ86 – C140 – 90

Содержание LN1GBQ41

Страница 1: ...ADVANCE SUSTAINABLE COMFORT MW 2000880 2 en User Guide control box equipped with a DIEMATIC Evolution for C140 boiler LN1GBQ41 C140 45 LN1GBQ62 C140 65 LN1GBQ86 C140 90...

Страница 2: ...sing the product and keep it in a safe place for later reference In order to ensure continued safe and efficient operation we recommend that the product is serviced regularly Our service and customer...

Страница 3: ...t configuration 16 5 5 Changing the room temperature of a zone 17 5 5 1 Definition of zone 17 5 5 2 Changing the name and symbol of a zone 17 5 5 3 Changing the operating mode of a zone 18 5 5 4 Timer...

Страница 4: ...cal data 29 9 Appendix 31 9 1 Product fiche 31 9 2 Product fiche Temperature Controls 31 9 3 Package fiche Boilers 32 9 4 EC Declaration of Conformity 33 Contents 4 DIEMATIC Evolution C140 7745361 v02...

Страница 5: ...1 Do not use a naked flame do not smoke do not operate electrical contacts or switches doorbell light motor lift etc 2 Shut off the gas supply 3 Open the windows 4 Locate the probable leak and seal i...

Страница 6: ...ettings the domestic hot water temperature may exceed 65 C 1 1 2 Safety instructions for the user Danger If you smell gas 1 Do not use a naked flame do not smoke do not operate electrical contacts or...

Страница 7: ...it turns out to be damaged it must be replaced by the manufacturer its after sales service or persons with similar qualifications in order to obviate any danger Caution A disconnection device must be...

Страница 8: ...quirements of the various Directives applicable They are therefore delivered with the marking and any documents necessary In the interests of the quality of our products we strive constantly to improv...

Страница 9: ...result in minor personal injury Caution Risk of material damage Important Please note important information See Reference to other manuals or pages in this manual 2 1 2 Symbols used on the appliance 1...

Страница 10: ...3 Control panel description 3 3 1 Control panel components 1 Rotary knob to select a tile menu or setting 2 Confirm button to confirm the selection 3 Back button Short button press Return to the previ...

Страница 11: ...screen actual position in the menu B Available menus C Brief explanation of the selected menu Tab 1 Available menus for the user Description Icon System Settings Version Information Meaning of the ic...

Страница 12: ...etting Temporary overwrite of the timer program is enabled The room temperature is changed temporarily The holiday program including frost protection is active The room temperature is reduced during y...

Страница 13: ...hey request heat 4 Check the hydraulic pressure in the installation shown on the control panel display Recommended hydraulic pressure between 0 15 and 0 2 MPa 1 5 and 2 0 bar Important In the event of...

Страница 14: ...example to 10 C If the temperature of the central heating water in the boiler drops too low the built in boiler protection system is activated This system works as follows If the water temperature is...

Страница 15: ...change will appear in the display Cannot edit read only datapoint will appear in the display if a setting cannot be changed Tab 4 Selectable tiles for the user Tile Menu Function Information menu Read...

Страница 16: ...able Select the heating circuit you want to configure by selecting the tile or Tab 5 Menu to configure a heating circuit Icon Menu Function Scheduling Set the scheduling mode and choose a timer progra...

Страница 17: ...actory symbol and factory name You can change the name and symbol of a zone 1 Select the tile of the zone you want to change 2 Press the button to confirm the selection 3 Use the rotary knob to select...

Страница 18: ...confirm the selection 5 5 4 Timer program to control the room temperature Creating a timer program A timer program allows you to vary the room temperature per hour and per day The room temperature is...

Страница 19: ...rt of the activity Activity Temperature setpoint 1 6 30 Morning 20 C 2 9 00 Away 19 C 3 17 00 Home 20 C 4 20 00 Evening 22 C 5 23 00 Sleep 16 C Changing the name of an activity You can change the name...

Страница 20: ...erature 8 Press the button to confirm the selection 5 5 6 Changing the room temperature temporarily Regardless of the operating mode selected for a zone it is possible to change the room temperature f...

Страница 21: ...lect the timer program you want to modify Schedule 1 Schedule 2 or Schedule 3 7 Press the button to confirm the selection Activities scheduled for Monday are displayed The last scheduled activity of a...

Страница 22: ...ot water sensor is installed 1 Select the tile 2 Press the button to confirm the selection 3 Use the rotary knob to select Hot water boost 4 Press the button to confirm the selection 5 Set the duratio...

Страница 23: ...ble daylight saving time Installer Details Read out the name and phone number of the installer Set Heating Activity Names Create the names for the activities of the timer program Set Screen Brightness...

Страница 24: ...than 0 08 MPa 0 8 bar the bar symbol flashes 2 Top up the heating system with water to increase the hydraulic pressure Important The recommended hydraulic pressure when cold is between 0 15 MPa 1 5 ba...

Страница 25: ...filling draining valve Leave the hose on the filling draining valve until the central heating system has been vented Important Topping up the water will add air to the central heating system Vent the...

Страница 26: ...k from the lowest to the highest 7 Open the venting valve with the bleed key keeping a cloth pressed against the vent Warning The water may still be hot 8 Wait until water comes out of the venting val...

Страница 27: ...point Place the end of the hose in a drain or at a place where drained pipe water will not cause any damage 5 Open the central heating system filling draining valve Drain the installation Warning The...

Страница 28: ...ontrol panel shows 1 The display will show a corresponding code and message 2 The status LED of the control panel will show Continuous green Normal operation Flashing green Warning Continuous red Bloc...

Страница 29: ...C 110 6 110 4 108 1 Part load heating mode efficiency GB20665 2015 return temperature 30 C 108 0 107 8 107 9 1 Factory setting Tab 14 Gas and flue gas values C140 C140 45 C140 65 C140 90 G20 gas cons...

Страница 30: ...lectrical data C140 C140 45 C140 65 C140 90 Supply voltage AC V 220 220 220 Power consumption full load max W 68 92 124 Power consumption low load max W 17 25 24 Power consumption standby max W 5 6 5...

Страница 31: ...nsumption GJ 124 190 Sound power level LWA indoors dB 55 55 61 1 No ErP information needs to be provided for heating boilers above 70 kW See For specific precautions about assembling installing and ma...

Страница 32: ...e products in relation to building size and characteristics Boiler and supplementary heat pump installed with low temperature heat emitters at 35 C Seasonal space heating energy efficiency class of pa...

Страница 33: ...orage tank II package with hot water storage tank 0 0 0 0 1 0 3 0 37 0 2 0 55 0 70 0 3 0 75 0 85 0 4 0 85 0 94 0 5 0 95 0 98 0 6 0 98 1 00 0 7 1 00 1 00 1 The intermediate values are calculated by lin...

Страница 34: ...9 Appendix 34 DIEMATIC Evolution C140 7745361 v02 15062020...

Страница 35: ...al and technological information contained in these technical instructions as well as any drawings and technical descriptions supplied remain our property and shall not be multiplied without our prior...

Страница 36: ...46 801 080 881 Infocentrala NEUBERG S A LU DE DIETRICH SERVICE AT DE DIETRICH CN www neuberg lu www dedietrich heating com www dedietrich heiztechnik com 352 0 2 401 401 0800 201608 freecall 39 rue Ja...

Отзывы: