1.3 Technical data - Heat pump water heaters
Tab.1
Technical parameters for heat pump water heaters
TWH 200 E
TWH 300 E
TWH 300 EH
Daily electricity consumption
Q
elec
kWh
3.677
5.761
5.850
Declared load profile
L
XL
XL
Sound power level, indoors
(1)
L
WA
dB(A)
57
57
57
Storage volume
V
l
217.0
271.0
265.0
Mixed water at 40°C
V40
l
289
384
380
(1) If applicable.
1.4 Circulation pump
Note
The benchmark for the most efficient circulators is EEI ≤ 0.20.
1.5 Disposal and Recycling
Warning
The thermodynamic water heater must be dismantled and scrap
ped by a qualified professional in accordance with prevailing local
and national regulations.
1. Switch off the thermodynamic water heater.
2. Cut the mains electricity supply to the thermodynamic water heater.
3. Close the water mains.
4. Drain the installation.
5. Dismantle the thermodynamic water heater.
6. Scrap or recycle the thermodynamic water heater in accordance with
local and national regulations.
1.6 Product fiche - Heat pump water heaters
Tab.2
Product fiche for heat pump water heaters
TWH 200 E
TWH 300 E
TWH 300 EH
Declared load profile
L
XL
XL
Water heating energy efficiency class under average climate
conditions
A
A
A
Water heating energy efficiency under average climate condi
tions
%
129.00
135.00
132.00