3. Use the
(
and
)
keys to switch from one measurement to
another.
Parameters Description
Unit
SE 01
Top DHW temperature sensor
°C
SE 02
Middle DHW temperature sensor
°C
SE 04
Room sensor
°C
SE 05
Evaporator temperature sensor
°C
SE 06
Electricity tariff:
4
HP1: Peak hours
4
HC0: Off-peak hours
St Su
Operating status / sub-status of the control system
sequence
SP 1
Back-up setpoint
°C
SP 2
Compressor setpoint
°C
5.2.2.
Counters
n
Displaying the counters
1. Press once the
MENU
key. The
SE nS 1
menu is displayed.
2. Press the
)
key 3 times. The
Co un 4
menu is displayed.
3. Press the
MODE
B
key to go to the Counters menu. The number
of the counter is shown to the right of the display.
4. Use the
(
and
)
keys to switch from one counter to another (See
table below).
5. To exit this menu, press the
MODE
B
key.
6. To go back to the main display, press the
MENU
button.
Meter Description
Unit
1
Total electric energy consumed for DHW production
kWh
2
Electric energy consumed by the compressor in the last 24 hours
The counter is reset at 00:00 hours every day
Wh
3
Electric energy consumed by the electrical back-up in the last 24 hours
The counter is reset at 00:00 hours every day
Wh
C003206-D
1x
2x
3x
.
.
.
1
4
3
4
1
2
MENU
MODE
C004186-A
1
4
3
4
1
2
MENU
MODE
C003210-C
1
1
4
3
4
1
2
MENU
MODE
5. Operating the appliance
TWH 200E TWH 300E TWH 300EH
19
01/12/2015 - 7605313-001-07