Commissionning

The first start-up is to be performed by your installation
engineer

`

Open the outlet and return valves

`

Throw the main switch

`

Open the gas valve

`

Control switch 1 : Position 

8

. The boiler launches the start-up

programme. The rest of the operation is automatic. The current
operating status is shown on the display.

`

Check the pressure of the installation. Add water to the

installation if necessary.

The boiler is bled automatically.
After a prolonged shutdown, up to 5 start-up attempts may be made.
If the boiler does not start, the burner control module goes into error
mode and a message is displayed.

`

Press the resetting button of the burner 2.

If the boiler does not start after several resets (5 attempts possible),
contact your heating engineer and inform him of the error message
displayed.
The boiler operates according to the settings programmed in the
factory.

Automatic mode

• Flap closed

• Daytime temperature setting

`

Press key 

2%

`

Enter the desired temperature (5-30°C) using the + and - keys

and save using the AUTO key.

• Reduced temperature setting

`

Press key 

2$

`

Enter the desired temperature (5-30°C) using the + and - keys

and save using the AUTO key.

If the installation includes a B or C circuit: press the 

2%

 and 

2$

keys
1x = input for circuit A
2x = input for circuit B
3x = input for circuit C
• Setting the domestic water temperature

`

Press key 

2

`

Enter the desired temperature (10-80°C) using the + and - keys

and save using the AUTO key.

• Flap  open

• Selection of the heating programme

`

Lift the flap

`

Set the desired heating programme P1-P4 using the PROG key

*The heating programmes programmed in the factory can be set
individually.

`

Close the flap

Standard factory programming

Program

Daytime operation

P1

Monday-Sunday 6-22 hours

P2*

Monday-Sunday 4-21 hours

P3*

Monday-Friday 5-8 hours; 16-
22 hours
Saturday-Sunday 7-23 hours

P4*

Monday-Friday 6-8 hours; 11-
13 hours 30, 16-22 hours
Saturday 6-23 hours
Sunday 7-23 hours

Содержание INNOVENS MC 35E

Страница 1: ...MC 35E MC 45 MC 65 MC 90 Wall hung gas condensation boilers Instructions for use INNOVENS English 21 03 05...

Страница 2: ...lified fitter Check that the equipment is properly set for the type of gas used Keep to the polarity shown on the terminals phase L neutral N and earth 4 Check the seal on the gas and water pipe conne...

Страница 3: ...programme a direct circuit and two circuits with mixing valve Monoblock heat exchanger in cast aluminium silicium Cylindrical premix burner covered in metal fibres Centrifugal fan with combustive air...

Страница 4: ...or a calorifier heating not allowed period 3 Dark area indicates comfort heating period or a calorifier heating allowed period 4 Flashing cursor showing the current time 5 Number display current time...

Страница 5: ...side temperature exceeds the outside heating shutdown temperature in this case only the symbol Su appears in the display 6 STANDARD Standard program key Pressing the STANDARD key for 5 seconds activat...

Страница 6: ...ccording to the settings programmed in the factory Automatic mode Flap closed Daytime temperature setting Press key 2 Enter the desired temperature 5 30 C using the and keys and save using the AUTO ke...

Страница 7: ...played above key Permanent heating domestic hot water Press key for 5 sec The operating mode is displayed above key Return to the automatic domestic hot water programme Press key Manual summer mode Ac...

Страница 8: ...iler Press the resetting button of the burner If interruptions of this kind happen repeatedly contact your fitter It is possible that the combustion products evacuation pipe is totally or partially ob...

Страница 9: ...requirements relating to the installation such as national and or local regulations the manufacturer s instructions in particular those relating to the regular maintenance of the unit the rules of the...

Страница 10: ...INNOVENS MC 35E MC 45 MC 65 MC 90 21 03 05 300005222 001 A...

Страница 11: ...INNOVENS MC 35E MC 45 MC 65 MC 90 21 03 05 300005222 001 A...

Страница 12: ...terest of customers De Dietrich Thermique SAS are continuously endeavouring to make improvements in product quality All the specifications stated in this document are therefore subject to change witho...

Отзывы: