DeDietrich EASYMATIC Скачать руководство пользователя страница 13

3/3

E control panel

CONTROL PANEL

1

8578-7001

Complete Easymatic control panel 

2

8578-8506

Complete Easymatic card cover

3

9786-4039

Easymatic front panel

4

9532-5027

Green On/Off two-pole switch

5

8500-0035

Two-pole switch

6

9532-5028

Moment inverter two pole switch

7

8500-0032

110°C safety thermostat

8

8500-0002

30-90 °C setting thermostat

9

9752-5181

Setting button

10

9534-0288

Circuit breaker 4A TS710/4A

11

9536-5147

Flat thermometer

12

9521-6220

Red light

13

8806-7511

Easymatic module CDC 2

14

9655-0352

WSBH-2 harness fastening

15

8575-8019

Board supports 

16

8578-4905

Diematic Easy Standard harness

17

8578-4906

Burner cable

18

8806-5565

Easymatic relay board

19

8575-4905

3-pin connector power supply

20

8575-4922

4-pin connector power supply VA+CS

21

8575-4924

Pump 3-pin connector A/VS

22

8575-4918

2-pin connector boiler sensor

23

8575-4911

EPT2-pin connector room sensor

24

8575-4928

EPT connector RT

25

8575-5520

Control panel screw bag

26

9655-0357

8-pin flat cable L = 300

27

8575-4918

KVT 60 sensor - lenth 1 m

EXTERNAL SENSOR 

950

8575-7741

External sensor (Package FM46)

951

9536-2450

External sensor AF60

952

8575-4906

2-pin external sensor connector

DHW SENSOR OPTION (PACKAGE FM 45)

990

8575-7740

D.h.w. sensor (Package FM 45) 

991

8575-4935

Installed d.h.w. sensor

992

8575-4909

D.h.w. sensor 2-pin connector

993

9536-2448

KVT 60 sensor L = 5M 

994

8575-4925

2-pin external connector d.h.w. sensor

995

9536-5613

Contact spring for thimble tube

Mark. Code No.

DESCRIPTION

Mark. Code No.

DESCRIPTION

10/09/03

Содержание EASYMATIC

Страница 1: ...E Control panel Package MA2 Easymatic English 03 14 08 94862243 Instructions for use Electrical connection Start up Please read these instructions and retain for future reference...

Страница 2: ...URES 7 5 SETTING THE TIME AND DAY 7 6 PROGRAMING 8 6 1 Factory programing 8 6 2 Program customization 8 7 MESSAGES ALARMS 9 8 STARTUP OR RESTART AFTER A PROLONGED STOP 10 9 ISOMETRIC VIEWS AND LIST OF...

Страница 3: ...re by controlling the burner The boiler thermostat must be set to a sufficiently high tempera ture for automatic regulation to operate correctly set ting between mark 8 and 9 The safety thermostat wit...

Страница 4: ...uring which the heating is to be cut off D 2 position switch AUTO automatic operation manual forced operation E Test STB push button When pushed and held in safety thermostat tests and cutoff of the h...

Страница 5: ...t free operation during the pro gramed time stop manual heating production of domestic hot water only if a calori fier is connected Key To force heating of the domestic hot water tank out side the d h...

Страница 6: ...operation the boiler temperature is no longer limited by the regulation the boiler thermostat G is used to regulate the boiler temperature the heating pump and the domestic hot water load pump if ther...

Страница 7: ...ressed Tempe Setting range Factory rature setting Domestic hot 40 to 60 C 50 F to 175 F water Adjustment in steps of 55 C 130 F average 1 C 5 F using storage and temperature Tempe Setting range Factor...

Страница 8: ...tically copied to other days but it can be modified individually day by day Write dark areas using the key and write light areas using the key 1 2 hour by 1 2 hour Dark areas are applicable to comfort...

Страница 9: ...AL L S S1 1 The entire installation automatically changes to Manual mode The burner is controlled by the boiler thermostat G The heating pump runs permanently and the valve is no longer regulated elec...

Страница 10: ...e heating program and the d h w program as you wish if you have domestic hot water production see chapter 6 Check that the switch D is in the AUTO position Check that the thermostat G is in the AUTO p...

Страница 11: ...ference 8578 4017 MODE 1 2 3 4 5 6 7 0 2 4 6 8 10 12 14 16 18 20 22 24 8578N027 17 3 15 26 27 13 25 2 19 16 20 21 18 22 23 24 29 28 1 4 12 11 9 8 6 5 10 7 14 AD042B DE DIETRICH THERMIQUE S A S au capi...

Страница 12: ...DHW SENSOR OPTION PACKAGE FM 45 E EASYMATIC control panel 990 992 995 994 993 991 85757740A EXTERNAL SENSOR 85757741 951 950 952 2 3...

Страница 13: ...tic relay board 19 8575 4905 3 pin connector power supply 20 8575 4922 4 pin connector power supply VA CS 21 8575 4924 Pump 3 pin connector A VS 22 8575 4918 2 pin connector boiler sensor 23 8575 4911...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...www dedietrich boilers com www dedietrichthermique com...

Страница 17: ...ing the supplied accessories 2 CB 4 wood screws inserts 8800N002A 8800N003 Positions to be avoided Installing the outside sensor The outside sensor is installed on the outside wall adja cent to the he...

Страница 18: ...is purpose at the back of the boiler control panel The connecting cables may be brought inside the boi ler through the cut outs provided in the boiler back panel which may be used along with purchased...

Страница 19: ...13 o 23 22 o o o 15 14 17 16 o o 19 18 o o o 21 20 o SENSOR MAIN SUPPLY 120V 60Hz SAFETY CONTACT 6 7 L N HEATING PUMP 8 9 10 LOAD PUMP 11 12 13 ALARM INDICATOR o 23 22 o 8578N008 S EXT 2 1 C Alim L S...

Страница 20: ...ALI 1 2 3 4 5 CS SAFETY CONTACT 6 7 L N HEATING PUMP 8 9 10 LOAD PUMP 11 12 13 o 23 22 o EXTERNAL S EXT o o 15 14 BOILER S CH 17 16 o o DOMESTIC HOT WATER S ECS 19 18 o o ROOM CIRCUIT A S AMB A o 21 2...

Страница 21: ...he same operations as for disassembly in the reverse order 5 4 3 2 1 The remote control will be installed adjacent to an internal partition about 1 5 m above the floor in a judi ciously chosen control...

Страница 22: ...arefully clip the connector onto the P C B The tabs on the base are different widths so that an inverted connection is impossible Screw the back part of the regulator to the control panel Fix the fron...

Страница 23: ...minutes or when you press the MODE key STANDARD MODE PROG PROG 1 2 3 4 5 6 7 0 2 4 6 8 10 12 14 16 18 20 22 24 8575N078 The settings given below are applicable to various functions and the installatio...

Страница 24: ...th easymatic control module installed 3 0 to 10 in the heated volume 9 9 Choose Low Night or Night Off mode 0 night stop only with room sensor influence 0 1 1 night low 1 10 0 Frost free ambiance set...

Страница 25: ...nto account slightly 3 taken into account medium amount recom mended 10 operation as room thermostat Parameter 9 NIGHT To select one of the following functions for operation at reduced rate if the roo...

Страница 26: ...ely hot water from entering the heating circuit after the calorifier heating has been stopped It also prevents overheating in the boiler which could accidentally trip the safety thermostat Parameter 1...

Страница 27: ...ECS LOAD PUMP CONTROL RELAY RL PA HEATING PUMP CONTROL RELAY S AMB A ROOM SENSOR S CH BOILER SENSOR S EXT EXTERNAL SENSOR S ECS DOMESTIC HOT WATER SENSOR TELEPHONE RELAY END SWITCH T TRANSFORMER TCH B...

Страница 28: ...rio N3E 1A3 CANADA Tel 519 650 0420 Fax 519 650 1709 In USA or South America 1054 North DuPage Avenue Lombard Illinois USA 60148 Tel 630 953 2374 Fax 630 953 2376 Toll Free 1 800 943 6275 www dedietri...

Отзывы: