1 / INSTALLING YOUR APPLIANCE
Your appliance should be positioned so that the mains switch is accessible.
These hobs must be connected to the mains using a socket in compliance with publication CEI
60083 or an all-pole circuit-breaker device in compliance with the installation rules in force.
When power is first supplied to your hob, or after an extended power cut, an indicator light will
appear on the control panel. This information will disappear after 30 seconds.
Connection
•Hook-up of 220-240V
~
(DTI11177X -DTI1137X - DTI1047C et GC)
Warning
If the cable is damaged it must be replaced by the manufacturer, its after-sales serv-
ice or a person with a similar qualification to prevent danger.
N
L
Green/yellow
Blue
Brown
32A
Earth
Neutral
Phase
Neutral
Phase
N
L
Green/yellow
Blue
Brown
• 220-240 V monophase
hook-up(DTI1177X)
Earth
Bleu
Brown
Green/yellow
Earth
Phase
L
20 A
32 A
Green/yellow
Blue
Brown
Earth
Blue
Brown
Green/yellow
Neutral
N
Phase
L
32 amp fuses.
63 amp fuse.
Neutral
N
Separate the 2 phase wires L1 and L2 before
connection
N
L
Green/yellow
Blue
Black - grey
Brown
Neutral
Earth
Phase
N
L1 L2
Blue
Green/yellow
Black - grey
Brown
•
220-240V
~
With hook-up of 400 V 2N three phase, verify
that the neutral wie is properly connected
• 400V 2N
~
-
16A
32A
Separate the wires before connection
Neutral
Earth
Phase
N1
L1 L2
Blue
Green/yellow
Black - grey
Brown
•
2x230V 2L+2N
~
-
16A
N2
Earth
Neutral
Phase
Connection DTI1043XE - DTI1167XE