2. 

Safety instructions and recommendations

2 Safety instructions and recommendations

2.1 Safety instructions

„

Fire hazard

Do not stock products of an inflammable nature close to
the appliance.

If you smell gas, do not use a naked flame, do not smoke,
do not operate electrical contacts or switches (doorbell,
lights, motor, lift, etc.).
1.

Shut off the gas supply

2.

Open the windows

3.

Extinguish all flames

4.

Evacuate the premises

5.

Contact a qualified professional

6.

Inform the gas supplier

„

Risk of intoxication

Do not obstruct the air inlets in the room (even partially).

If you smell flue gases
1.

Switch the appliance off

2.

Open the windows

3.

Evacuate the premises

4.

Contact a qualified professional

„

Risk of being burnt

Avoid direct contact with the flame viewport.

Depending on the settings of the appliance:

- The temperature of the flue gas conduits may exceed 60°C
- The temperature of the radiators may reach 95°C
- The temperature of the domestic hot water may reach 65°C

„

Risk of damage

Do not stock chloride or fluoride compounds close to the
appliance.

Install the appliance in frost-free premises.

Do not neglect to service the appliance: Contact a qualified
professional or take out a maintenance contract for the annual
servicing of the appliance.

2.2 Recommendations

Only qualified professionals are authorised to work on the
appliance and the installation.

Before any work, switch off the mains supply to the
appliance.

Check regularly that the installation contains water and is
pressurised.
Keep the appliance accessible at all times.
Avoid draining the installation.
The appliance should be on Summer or Antrifreeze mode rather than
switched off to guarantee the following functions:

- Antifreeze protection
- Protection against corrosion on domestic hot water tanks fitted

with a titanium anode

Содержание DTG 330

Страница 1: ...DTG 330 S Low temperature gas boiler User Guide 300011852 02 en...

Страница 2: ...K3 control panel 8 4 2 Changing the settings 8 4 2 1 B3 control panel 8 4 2 2 DIEMATIC m3 control panel 9 4 2 3 K3 control panel 10 4 3 Switching off the boiler 10 4 3 1 Precautions to take if there...

Страница 3: ...peration of your appliance We are sure that it will be entirely to your satisfaction and will meet with all of your expectations Keep these instructions in a safe place close to the appliance For a pr...

Страница 4: ...ttings of the appliance The temperature of the flue gas conduits may exceed 60 C The temperature of the radiators may reach 95 C The temperature of the domestic hot water may reach 65 C Risk of damage...

Страница 5: ...panel 2 Safety box 3 Multivalve gas unit Safety valve Main valve Filter Minimum gas pressure switch 4 Ignition valve 5 Ignition burner 6 Flame inspection window 7 Ionization probe 8 Ignition electrode...

Страница 6: ...ation Position TEST STB Temporary action to test the safety thermostat 4 Safety thermostat with manual reset Set to 110 C 5 Timed circuit breaker 4 A 6 Pump shutdown switch 7 Electronic thermostat 30...

Страница 7: ...isplay 2 Graphic display bar for the programme in circuit A B or C 3 Light area Reduced temperature heating period or tank load disabled 4 Dark area Comfort temperature heating period or tank load ena...

Страница 8: ...s from the DIEMATIC m 3 regulation into account The boiler is regulated by the boiler thermostat s TEST STB Temporary action to test the safety thermostat 4 Safety thermostat with manual reset Set to...

Страница 9: ...rious counters number of burner start ups number of burner operating hours etc 2 Set temperatures Day Heating DHW Pool 2 Set temperatures Night Heating DHW Access key to the secondary boilers Control...

Страница 10: ...water pressure in the installation Top up with more water if necessary 2 Open the gas valve 3 Make the settings on the control panel B3 control panel Turn the switch TEST STB to Turn the pump shutdow...

Страница 11: ...ollowing maintenance at least 1 time a year Cleaning main burner and ignition burner Cleaning of the heating body Cleaning painted surfaces Cleaning the gas filter 6 Troubleshooting 6 1 Type plate Bef...

Страница 12: ...d by the boiler thermostat and the heating and DHW circuits operate normally Advise the installer OUTSI S FAIL The sensor circuit has been broken or short circuited The boiler setting is equal to BOIL...

Страница 13: ...e burner Call your fitter The burner is operating but the radiators are cold Bleed the radiators Top up the primary circuit with water If it is often necessary to top up the installation with water co...

Страница 14: ...t Lower the thermostat by 3 4 C Use the sun s heat as much as possible Take showers rather than baths Use a water saving shower head DTG 330 S 8 9 10 11 12 14 16 18 20 Useful output DTG 330 S Stage 1...

Страница 15: ...dispositions are not exclusive of benefits for the purchaser of the legal guarantee as stated in Civil Code articles 1641 to 1648 Poland Warranty conditions are included in the warranty card Switzerla...

Страница 16: ...iclima it www dedietrich cz Distributore Ufficiale Esclusivo De Dietrich Thermique Italia www dedietrich heiztechnik com Freecall 0800 201608 Jeseniova 2770 56 130 00 Praha 3 49 0 25 72 9161 0 49 0 25...

Отзывы: