25
-
Connection via a flexible metal
hose (stainless steel) with screw
connectors
(meeting standard NF D 36-
121) ; the life of such hoses is not limited.
-
Connection with a flexible
reinforced rubber hose with
mechanical screw connectors
(meeting standard NF D 36-103) with a
10-year life.
When connecting the gas to your
hob, if you have to change the
direction of the elbow fitted into the
appliance:
- change the seal.
- tighten the nut on the elbow ensuring
that you do not exceed a tightening
torque of 17 N.m.
• Gas supplied from a cylinder or tank
(butane/propane gas) (1.3.2).
For your safety, you must choose only
one of the following three connections:
-
Connection via a rigid copper pipe
with mechanical screw connectors (½"
gas standard). Connect directly to the
elbow on the appliance.
-
Connection with a flexible metal
hose (stainless steel) with screw
connectors
(to standard NF D 36-125);
the life of such hoses is not limited.
-
Connection with a reinforced
flexible rubber hose with mechanical
screw connectors
(meeting standard
NF D 36-112) with a 10-year life.
1
2
2
1
In an existing installation, a flexible
hose fitted with jubilee clips
(meeting
standard XP D 36-110) whose service life
is limited to 5 years may be used. In this
case an end connector must be used with
a sealing washer
fitted between the
end connector
and the elbow on the
hob.
You can purchase the end connector
and the sealing washer from your
after-sales department.
Tighten the end connector to a torque not
exceeding 25 N.m.
1.4 - CHANGING THE TYPE OF GAS :
Your appliance is supplied ready
for use with natural gas.
The injectors required for adapting it
to butane/propane can be found in the
plastic bag containing this guide.
Whenever you change the gas type, you
must follow these steps in turn:
- Change the gas connection,
- Change the injectors,
- Adjust the retarder on the taps.
1• To change the gas connection
:
- refer to the "Gas connection“ paragraph.
2 •
Change the injectors
, proceeding as
follows:
- Remove all the supports, burner caps
and heads.
- Unscrew the injectors
, in the bottom
of each well, using the spanner provided
and remove them
(1.4.1).
C
A
B
A
B
3
•
1
INSTALLATION
Содержание DPG7549 Series
Страница 2: ...3 10 kW G20 0 85 kW G20 3 8 kW G20 0 1 0 1 1 DPG7549 0 D C F...
Страница 4: ...1 4 1 4 1 1 4 2 1 4 3 1 2 1 2 1 1 3 1 3 1 1 3 2 1...
Страница 7: ...1 6 1 1 1 6...
Страница 8: ...2 2 1 2 1 1 2 1 2 2 1 3 2 2 1 4...
Страница 9: ...6 1 1 6 1 6 3 1 3 1 1 3 1 2 3...