background image

7. To go back to the main display, press key 

j

2 times.

It is possible to use the 

(

 and 

'

 keys instead of the rotary

button.

bar

1

1

2

2

r

c

STD

(

'

t

v

0

2

4

6

8

10

12

14

16

18

22

24

20

p

b

AUTO

x c

r

j

M

g

m

LUNDI 11:45

C002224-D-04

2x

3. Description

AWHP MIT-IN iSystem

13

06/09/2012  - 300027618-001-01

Содержание AWHP 11 MR

Страница 1: ...HPI EN Air water heat pump AWHP MIT IN iSystem User Guide 300027618 001 01...

Страница 2: ...al description 8 3 2 Control panel 8 3 2 1 Description of the keys 8 3 2 2 Description of the display 9 3 2 3 Browsing in the menus 12 4 Operating the appliance 14 4 1 Putting the appliance into opera...

Страница 3: ...6 Technical specifications 28 6 1 Technical specifications 28 6 1 1 Electricity supply 28 6 1 2 Heat pump 28 6 1 3 Sensor characteristics 29 7 Energy savings 30 7 1 Energy savings 30 7 1 1 Energy savi...

Страница 4: ...3 06 09 2012 300027618 001 01...

Страница 5: ...situation causing slight physical injury CAUTION Risk of material damage Signals important information Signals a referral to other instructions or other pages in the instructions 1 1 2 Symbols used o...

Страница 6: ...4 Room temperature instruction Temperature programmed in the control system that must be reached by the heat pump 1 3 General 1 3 1 Manufacturer s liability Our products are manufactured in complianc...

Страница 7: ...on qualified professionals to carry out installation and initial start up 4 Get your installer to explain your installation to you 4 Have the required checks and services done 4 Keep the instruction m...

Страница 8: ...ontact a qualified professional or take out a maintenance contract for the annual servicing of the appliance 2 2 Recommendations WARNING Only qualified professionals are authorised to work on the appl...

Страница 9: ...ing advantages 4 The heating circuit is housed in the insulated volume within the home There is no danger of the pipes freezing 4 Thanks to the DC inverter system the heat pump modulates its output to...

Страница 10: ...s available f Used to display the curve of the parameter selected STD Reset of the time programmes b Selection of comfort mode or selection of the days to be programmed v Selection of reduced mode or...

Страница 11: ...4 Steady symbol Permanent override g Holiday mode The symbol is displayed when a HOLIDAY override antifreeze is activated 4 Flashing symbol Holiday mode programmed 4 Steady symbol Holiday mode active...

Страница 12: ...g symbol The heating pump on the back up boiler is commanded n Status of the compressor v 4 Steady symbol The compressor is running 4 Flashing symbol The heat pump is required but the compressor is of...

Страница 13: ...ify the parameter press the rotary button To go back to the previous display press the key j 5 To modify the parameter turn the rotary button 6 To confirm press the rotary button To cancel press key h...

Страница 14: ...j2 times It is possible to use the and keys instead of the rotary button bar 1 1 2 2 r c STD t v 0 2 4 6 8 10 12 14 16 18 22 24 20 pb AUTOxc r j M g m LUNDI 11 45 C002224 D 04 2x 3 Description AWHP MI...

Страница 15: ...rror is displayed on the screen See chapter Messages page 23 4 2 Reading out measured values The various values measured by the appliance are displayed in the MEASURES menu 1 To access user level Pres...

Страница 16: ...M TEMP 1 Temperature of the system flow water if multi generator C T DHW BOTTOM 1 Water temperature in the bottom of the DHW tank C TEMP TANK AUX 1 Water temperature in the second DHW tank connected t...

Страница 17: ...t B 16 C ROOMTEM COOL B 2 1 22 to 30 C Desired room temperature set point in cooling mode 25 C DAY TEMP C 2 5 to 30 C Desired room temperature in comfort periods on circuit C 20 C NIGHT TEMP C 2 5 to...

Страница 18: ...ndicated or all the time 7 7 Present time 1 hour HOLIDAYS 7 7 1 to 365 The antifreeze mode is active on all boiler circuits Number of days holiday xx 1 heating OFF xx xx 1 Restarting xx xx 1 Present d...

Страница 19: ...ast and lighting on the display 1 To access user level Press the key 2 Select the menu SETTING 4 Turn the rotary button to scroll through the menus or modify a value 4 Press the rotary button to acces...

Страница 20: ...y in March and back to winter time on the last Sunday in October AUTO MANU for countries where the time change is done on other dates or is not in use 1 According to the configuration 4 3 6 Selecting...

Страница 21: ...PROG A PROG P2 A PROG P3 A PROG P4 A Timer programme for circuit A TIME PROG B PROG P2 B PROG P3 B PROG P4 B Timer programme for circuit B TIME PROG C PROG P2 C PROG P3 C PROG P4 C Timer programme fo...

Страница 22: ...mode have been selected press the rotary button to confirm User level Menu TIME PROGRAM Day Comfort periods Filling enabled P1 _______________ P2 _______________ P3 _______________ P4 _______________...

Страница 23: ...heating system is not used for a long period we recommend switching the appliance off To stop the inside module use the J K ON OFF switch and cut the power supply on the house s junction box To shut...

Страница 24: ...onomously when the cause of the failure has been lifted 3 If the code is displayed again correct the problem by following the instructions in the table below Code Messages Description Checking solutio...

Страница 25: ...p 4 Contact the professional who takes care of maintenance of the appliance B19 BL NO CONFIG The inside module has not been configured The PSU PCB has been changed 4 Contact the professional who takes...

Страница 26: ...IT parameter The valve setting is no longer ensured but monitoring the maximum temperature of the circuit after the valve is ensured Valves may be manually operated Reheating the domestic hot water re...

Страница 27: ...nsor fault 4 Contact the professional who takes care of maintenance of the appliance D18 ST TANK S FAIL SCU Solar tank sensor fault Bad connection Sensor fault 4 Contact the professional who takes car...

Страница 28: ...rotected If a tank without Titan Active System is connected to the heat pump check that the TAS simulation connector delivered in package AD212 is fitted to the sensor board D99 DEF BAD PCU SCU The SC...

Страница 29: ...er A7 W35 1 kWe 1 5 2 1 2 6 2 6 3 4 3 4 4 03 4 03 4 9 6 3 Nominal amperage A7 W35 1 A 6 8 9 2 11 2 6 7 14 8 8 8 17 6 10 1 12 3 15 6 Calorific output A2 W35 2 kW 4 4 5 9 7 6 7 6 10 3 10 3 10 4 10 4 11...

Страница 30: ...Liquid Gas inch 1 4 1 2 3 8 5 8 3 8 5 8 3 8 5 8 3 8 5 8 3 8 5 8 3 8 5 8 3 8 5 8 3 8 3 4 or 3 8 1 1 2 3 4 or 1 2 1 Max pre loaded length m 30 30 30 30 30 30 30 30 30 30 Weight empty outside unit kg 45...

Страница 31: ...sumes twice as much water and energy 7 1 2 Room thermostat and settings 4 A modulating thermostat possibly in combination with thermostatic valve radiators saves energy and offers considerable comfort...

Страница 32: ...valve must be fully opened 4 Completely closing and opening thermostatic valve radiators causes undesirable temperature fluctuations Open and close thermostatic valves in small steps 4 Lower the tempe...

Страница 33: ...turer shall not be held responsible for any damage loss or injury caused by installations which do not comply with the following 4 applicable local laws and regulations 4 specific requirements relatin...

Страница 34: ......

Страница 35: ......

Страница 36: ...ch calefaccion es Av Princep d Ast ries 43 45 08012 BARCELONA 34 932 920 520 34 932 184 709 ES 129164 15 1 309 7 495 221 31 51 Copyright All technical and technological information contained in these...

Отзывы: