background image

4  Description of the product

4.1 

General description

Main components:

The tank is made of high quality steel and is lined with food safety quali­

ty enamel vitrified at 850°C, which protects the tank from corrosion.

The tank is protected against corrosion by an impressed current titanium 

anode (Titan Active System®).

The plate exchanger is a device that allows water/water exchange.

The appliance is insulated by CFC-free polyurethane foam, which re­

duces heat losses to a minimum.

The outside casing is made of painted steel sheeting.

The solar control system

The thermostatic mixing valve

Le préparateur d’eau chaude sanitaire 220 SHL est exclusivement pro­

posé en association avec les chaudières listées ci-dessous, il ne peut pas 

être utilisé en tant que préparateur indépendant :

AGC 10/15 - AGC 15, 25, 35

AGC 15 BE, 25 BE, 35 BE

GSCR 15, 25, 35

CALORA TOWER GAS 15S EX, 25S EX, 35S EX

CALORA TOWER GAS 35S

CALORA TOWER GAS 25S BE, 35S BE

CALORA TOWER GAS 15S DE, 25S DE, 35S DE

CALORA TOWER GAS 15Si BE, 25Si BE, 35Si BE

GiegaStar Compact 15, 25

CALORA TOWER OIL 18, 24, 30

CALORA TOWER OIL 18 LS, 24 LS, 30 LS

AFC 18, 24, 30

OSCR 18, 24, 30

OSCR 18 LS, 24 LS, 30 LS

Important

The energy labels, product fiches and technical specifications per­

taining to product packages are available on our internet site.

4.2 

Composition of the NF CESI solar system packages (only for France)

A system compliant with NF CESI certification is composed of a series of 

packages presented in the list below The references or package numbers 

listed must appear on the invoice for the system delivered to the customer 

to ensure traceability of the system.
A system is complete and functional according to the NF CESI mark if all 

system references appear on the invoice. The system is composed of the 

following elements:

A collector field with 1 or 2 solar collectors.

A boiler system (Modulens or OEnoviaGas Comfort / OEnoviaFuel Com­

fort) + solar domestic hot water tanks to which is factory fitted a solar 

station consisting of a circulating pump, an expansion vessel and a Die­

masol A / Oetrosol A regulator.

The solar fluid that protects the installation from frost and corrosion.

4  Description of the product

10

220 SHL

300028214 - v06 - 02022017

Содержание 220 SHL

Страница 1: ...en User manual Domestic hot water tank 220 SHL...

Страница 2: ...sing the product and keep it in a safe place for later reference In order to ensure continued safe and efficient operation we recommend that the product is serviced regularly Our service and customer...

Страница 3: ...r system packages only for France 10 4 3 Main components 19 5 Operation 20 5 1 Commissioning procedure 20 5 2 Frost protection 20 5 3 Shutting down the solar control system 20 6 Maintenance 21 6 1 Gen...

Страница 4: ...ater tap in the installation 3 Open a valve on the safety unit 4 When the water stops flowing the domestic hot water tank has been drained Warning Pressure limiter device The pressure limiter device s...

Страница 5: ...pipes is obligatory 1 2 Recommendations Have the installation regularly serviced to guarantee that it operates correctly over time Warning Never turn the power off to the solar control sys tem even fo...

Страница 6: ...tion manuals provided 2 Dispose of used products in an appropriate recovery and recycling structure 2 2 Abbreviations CFC Chlorofluorocarbon DHW Domestic Hot Water ICA Impressed current anode 2 3 Liab...

Страница 7: ...ser of the obligation to check the appliance and keep it in good working order Give all the instruction manuals to the user 2 3 3 User s liability To guarantee optimum operation of the system you must...

Страница 8: ...ponents safety 3 1 3 Directive 97 23 CE This product conforms to the requirements of European Directive 97 23 EC article 3 paragraph 3 on pressure equipment 3 2 Technical data 3 2 1 Specifications of...

Страница 9: ...uit heating water 80 C 3 Domestic cold water inlet 10 C Domestic hot water outlet 40 C Primary circuit heating water 80 C Tank temperature 60 C Tab 3 Performance linked to oil fired floor standing con...

Страница 10: ...E 35Si BE GiegaStar Compact 15 25 CALORA TOWER OIL 18 24 30 CALORA TOWER OIL 18 LS 24 LS 30 LS AFC 18 24 30 OSCR 18 24 30 OSCR 18 LS 24 LS 30 LS Important The energy labels product fiches and technica...

Страница 11: ...10 15 VH V220SHL AGC 10 15 VV V220SHL AGC 10 15 VH B220SHL AGC 10 15 VV B220SHL AFC 18 B220SHL AFC 24 B220SHL AFC 30 B220SHL AFC 18 FF HOR B220SHL AFC 18 FF VER B220SHL AFC 24 FF HOR B220SHL AFC 24 FF...

Страница 12: ...OR B220SHL AFC 24 FF VER B220SHL AFC 30 FF HOR B220SHL AFC 30 FF VER B220SHL ER220 100016425 100018125 100018127 100018126 100018128 100018129 100018131 100018130 100018132 100018133 100018135 1000181...

Страница 13: ...SHL AGC 10 15 VH V220SHL AGC 10 15 VV V220SHL AGC 10 15 VH B220SHL AGC 10 15 VV B220SHL AFC 18 B220SHL AFC 24 B220SHL AFC 30 B220SHL AFC 18 FF HOR B220SHL AFC 18 FF VER B220SHL AFC 24 FF HOR B220SHL A...

Страница 14: ...0SHL AFC 30 FF HOR B220SHL AFC 30 FF VER B220SHL ER220 100016425 100018125 100018127 100018126 100018128 100018129 100018131 100018130 100018132 100018133 100018135 100018134 100018136 100019292 10001...

Страница 15: ...R 25 VER 220SHL GCCR 25 VER 220SHL GVCR 35 VER 220SHL GCCR 35 VER 220SHL OCCR 18 220SHL OCCR 24 220SHL OCCR 30 220SHL OCCR 18 HOR 220SHL OCCR 18 VER 220SHL OCCR 24 HOR 220SHL OCCR 24 VER 220SHL OCCR 3...

Страница 16: ...R 24 VER 220SHL OCCR 30 HOR 220SHL OCCR 30 VER 220SHL ER220 100016425 100018232 100018234 100018236 100018238 100018240 100018242 100018232 100018234 100018236 100018238 100018240 100018242 100019381...

Страница 17: ...20SHL GVCR 25 VER 220SHL GCCR 25 VER 220SHL GVCR 35 VER 220SHL GCCR 35 VER 220SHL OCCR 18 220SHL OCCR 24 220SHL OCCR 30 220SHL OCCR 18 HOR 220SHL OCCR 18 VER 220SHL OCCR 24 HOR 220SHL OCCR 24 VER 220S...

Страница 18: ...220SHL OCCR 30 VER 220SHL ER220 100016425 100018232 100018234 100018236 100018238 100018240 100018242 100018232 100018234 100018236 100018238 100018240 100018242 100019381 100019382 100019383 10001940...

Страница 19: ...the spherical plug valve 8 Solar circuit heating pump 9 Glycol reservoir 10 Primary solar circuit filling and draining device 11 Primary solar coil sensor 12 Manual venting degasser 13 Primary solar...

Страница 20: ...from the boiler control panel When in use no direct action is needed on the DHW tank 5 2 Frost protection Warning Do not switch off the power supply Frost protection is guaranteed Protection of the t...

Страница 21: ...ed on an impressed current anode Warning The boiler control panel must be switched on to ensure that the impressed current anode operates Failure to follow this mainte nance requirement may lead to th...

Страница 22: ...the boiler s installation and service manual 6 7 Maintenance of the thermostatic mixer valve The thermostatic mixer valve does not require any particular maintenance 6 Maintenance 22 220 SHL 300028214...

Страница 23: ...t covers all manufacturing faults the warranty period will commence on the date of purchase stated on the installer s invoice The warranty period is stated in our price list As a manufacturer we can b...

Страница 24: ...stablished in European Directive 99 44 EEC implemented by legal decree No 24 of 2 February 2002 and published in Official Journal No 57 of 8 March 2002 remain in force 7 Warranty 24 220 SHL 300028214...

Страница 25: ...tic hot water tank 2 Disconnect the cables on the electrical components 3 Close the domestic water inlet valve 4 Drain the installation 5 Dismantle all water connections fitted to the domestic hot wat...

Страница 26: ...8 Appendix 26 220 SHL 300028214 v06 02022017...

Страница 27: ...nological information contained in these technical instructions as well as any drawings and technical de scriptions supplied remain our property and shall not be multiplied without our prior consent i...

Страница 28: ...300028214 v06 02022017 300028214 001 06...