Tab.14 Technical parameters for heat pump combination heaters (parameters declared for medium-temperature application)
Product name
200 ASL
Hybrid 8MR-2
+ AGC 25
200 ASL
Hybrid 11MR-2
+ AGC 25
200 ASL
Hybrid 16MR-2
+ AGC 25
Air-to-water heat pump
Yes
Yes
Yes
Water-to-water heat pump
No
No
No
Brine-to-water heat pump
No
No
No
Low-temperature heat pump
No
No
No
Equipped with a supplementary heater
Yes
Yes
Yes
Heat pump combination heater
Yes
Yes
Yes
Rated heat output under average conditions
(1)
Prated
kW
11
15
22
Rated heat output under colder conditions
(1)
Prated
kW
9
11
15
Rated heat output under warmer conditions
(1)
Prated
kW
6
8
13
Declared capacity for heating for part load at an
indoor temperature of 20 °C and outdoor temper
ature
T
j
T
j
= -7°C
Pdh
kW
5.6
6.8
9.0
T
j
= +2 °C
Pdh
kW
6.1
8.2
11.8
T
j
= +7 °C
Pdh
kW
6.4
9.0
12.9
T
j
= +12 °C
Pdh
kW
6.5
10.1
15.4
T
j
= bivalent temperature
Pdh
kW
6.1
8.2
11.8
T
j
= operation limit temperature
Pdh
kW
5.6
6.2
8.3
Bivalent temperature
T
biv
°C
2
2
2
Degradation co-efficient
(2)
Cdh
—
1.0
1.0
1.0
Seasonal space heating energy efficiency under
average conditions
ƞ
s
%
135
133
129
Seasonal space heating energy efficiency under
colder conditions
ƞ
s
%
125
122
120
Seasonal space heating energy efficiency under
warmer conditions
ƞ
s
%
169
167
161
Declared coefficient of performance or primary
energy ratio for part load at an indoor tempera
ture of 20 °C and outdoor temperature
T
j
T
j
= -7°C
COPd
-
or
%
1.95
1.82
1.88
T
j
= +2 °C
COPd
-
or
%
3.49
3.43
3.33
T
j
= +7 °C
COPd
-
or
%
4.57
4.54
4.34
T
j
= +12 °C
COPd
-
or
%
6.33
6.24
5.82
T
j
= bivalent temperature
COPd
-
or
%
3.49
3.43
3.33
T
j
= operation limit temperature
COPd
-
or
%
1.63
1.45
1.54
Operation limit temperature for air-to-water
heat pumps
TOL
°C
-10
-10
-10
3 Technical specifications
22
200 ASL HYBRID
7613348 - v06 - 10122018