Dedicated Micros ©2009
1
D
V-IP RT
Step Relays
The DV-IP RT supports up to four 24V 200mA relays.
Relay Connector
Pins
Connection
1 / 6
Relay 1 signal
2 / 7
Relay 2 signal
3 / 8
Relay 3 signal
4 / 9
Relay 4 signal
Step Alarms
The DV-IP RT supports 20 normally open/closed tamper proof alarm inputs, or one Global keyswitch
input with camera specific inputs configurable as entry/exit alarms. The alarms support tamper proof
detection using 1k in line and 5K end of line resistance. The DV-IP RT detects short circuit, open
circuit and contact closure. This functionality is part of the advanced alarms supported on NetVu
Connected products and includes features required for Central Monitoring. It is compatible with the
British Standard BS8418.
Relay Connector
Pin
Alarm Input Connection
1 - 20 1-20
21-25 Earth Common