OWNERS MANUAL for Model SE84UFO3 PAGE 13
!
SYMPTOM
CAUSES
REMEDIES
Popping or Spitting
noise
Noisy tube
Replace noisy tube
Wifi router or bridge
nearby
Locate away from audio
components
AC fuse blows
Line voltage surge
Replace fuse
Rectifier Tube Arced
on initial startup
If it continues, replace
rectifier tube and fuse.
Fuse is too small
Install correct amperage
fuse. If amperage IS
correct and fuse blows,
use a SLOW BLO fuse
of the same amperage.
One Channel stops
working
No signal to that
channel
Take the cable from the
channel that works and
put it into the channel
that stopped working. If
it starts working, the
amp is fine, but you
have either a bad cable
or problem with your
preamp or source
component.
Speaker cable came
unhooked
Reinstall speaker cable.
Output tube failed
Replace output tube.
Channel imbalance
Output tubes no
longer match
Replace output tubes
with a matched pair.
Input tube sections
no longer match
Replace input tube with
a new input tube that
has matched sections.
Speaker HI/LO
impedance switches
are not set the
same.
Adjust the HI/LO
switches the same for
each channel.
Troubleshoo?ng