Instruction Manual
Negative Pressure Unit smart dec
Version 2
Page 14
6. Assembly instruction
The Negative Pressure Unit is shipped ready-to-use from the factory and is intended for
immediate commissioning.
In case of visible damage, do
not
operate the unit.
Please contact deconta GmbH immediately.
Please note:
In principle, the negative pressure unit can also be operated directly in the
contaminated area (overpressure technology prevents the penetration of
contaminated ambient air into the housing).
Since the devices are contaminated from the outside and therefore have to be
cleaned after completion of the rehabilitation, a use in the contaminated area should
absolutely be avoided.
Integrate the device to the partition wall clean/ contaminated area
Insert approx. 100 mm into the contaminated area
Seal the device with the partition wall
Route the exhaust hose into the open air
Ensure adequate supply air in the contaminated area
clean area
contaminated area
supply
air