Instruction Manual
Negative Pressure Unit green dec
Version 1
Page 11
4.5. Performance data G 400
Air performance, free-blowing max.
9500 m³/h
+ deconta H13 or H14 filter
max.
8400 m³/h
+ pre- and intermediate filter
(EU3, EU4) max.
7800 m³/h
Power connection
400 V
Power consumption
5 A
Motor power
1,5 kW
Power cable type
16A CEE CEE add-on-device-connector
Protection class
I
Type of protection
IP 54
Filter system
3-stage
- pre-filter
EU 3
- intermediate filter
EU4
- HEPA filter
acc. to EN 1822 class H13 or H14
4.6. Performance data G 500
Air performance, free-blowing max.
15400 m³/h
+ deconta H13 or H14 filter
max.
13400 m³/h
+ pre- and intermediate filter
(EU3, EU4) max.
12800 m³/h
Power connection
400 V
Power consumption
5 A
Motor power
5,7 kW
Power cable type
16A CEE CEE add-on-device-connector
Protection class
I
Type of protection
IP 54
Filter system
3-stage
- pre-filter
EU 3
- intermediate filter
EU4
- HEPA filter
acc. to EN 1822 class H13 or H14