background image

 

 

Connecting Wall Panel  

WARNING 

To prevent SERIOUS INJURY or DEATH from electrocution: 
- Power MUST NOT be connected until instructed. 
To prevent SERIOUS INJURY or DEATH from using the Wall Panel or Push Button and a closing door: 
-  Install  the  Wall  Panel  or  Push  Button  within  sight  of  the  door  at  a  minimum  height  of  5  feet  (1.5m) 

above the floor. Make sure it is out of the reach of children and moving parts of door and hardware. 

- NEVER permit children to access the Wall Panel, Push Button or remote Transmitters. 
- Operate the door ONLY when it is adjusted properly with no obstructions present and is in clear sight. 
- ALWAYS keep a moving door in sight until it’s completely closed. 
- NEVER cross the path of a moving door.

 

Drywall Anchor

 

Screw #6 x1”

 

14 

The Wall Panel is a wired, illuminated door control placed inside 
your garage.

 

To install the Wall Panel: 

1. 

Inside your garage, install the rear cover of the Wall Panel 
within  sight  of  the  door  at  a  minimum  height  of  5  feet 
(1.5m) off the ground. Ensure it is installed out of the reach 
of children and free from the moving parts of the door and 
hardware. 

2. 

With the “Arrow” icon on the rear cover pointing to up, se-
curely fasten it to a solid surface with 1” screws. If attach-
ing to drywall or other hollow surface, drill 3/16” holes and 
use the provided Drywall Anchors. 

3. 

Snap the Wall Panel onto the rear cover

.

 

To Connect the Wall Panel to the Opener

 

Connect the pair of wires from the Wall Panel to the “Wall Box” 
terminals on the rear of the Opener. 

Using the Wall Panel  
(ONLY after installation is completed and power is connect-
ed as instructed.)

 

 

Door

—Momentary press to access the door 

 

Light

– Turns the courtesy light On/Off 

 

Vacation Lock   
OFF

 — Door can be accessed by either access controls 

 

 ON

 — Prevent access of door by Remote Transmitters  

and Door button   

 

From Wall Panel

 

Wall  
Box 

 

Wall Panel

 

Min. 5 feet (1.5m) above floor 

 

Arrow icon points UP

 

 

 

Connecting Power 

To Align the Photo Eye Safety System: 

1. 

When the Photo Eye System is properly connected and the 
power  is  connected,  one  of  the  Photo  Eyes  will  emit  a 
steady  green  light.  This  Photo  Eye  is  the  Emitter  that     
generates the Invisible Light Beam. 

2. 

When  properly  aligned,  the  Sensor  should  emit  a  steady 
red  light  when  it  senses  the  invisible  light  beam  from  the 
Emitter. 

3. 

If  the  indication  is  unsteady,  flashes  or  is  dim,  check  for 
any  obstructions  and  adjust  the  position  until  the  Sensor 
gives a STEADY RED LIGHT. 

Note:  The  path  of  the  invisible  light  beam  MUST  NOT  be  

obstructed.  No  part  of  the  garage  door  or  any       
hardware should interfere with the beam or the Open-
er will not close the door.

 

Aligning the Photo Eye Safety System 

For Permanent Wiring ONLY

 

DO NOT OPERATE OPENER AT THIS TIME. 

To Connect Power

 

Plug  the  Opener  into  a  grounded  outlet  ONLY.  If  there  is  no 
grounded outlet present, call a qualified electrician to replace the 
outlet.  

Permanent Wiring (If Required by Local Code)

 

1. 

Remove  the  enclosure  by  removing  the  6  screws  located 
on the sides and rear of the Opener. 

2. 

Cut the two  wire  connectors found inside  and  remove  the 
power cord. 

3. 

Group neutral (white) wires from power source with 2 white 
(W)  wires  and  1  yellow  (Y)  wire  inside  the  Opener.         
Connect them with a wire nut (not provided). 

4. 

Group line (black) wires from power source with black wire 
(B)  inside  the  Opener.  Connect  them  with  a  wire  nut      
(not provided). 

5. 

Secure  the  ground  (green  or  bare)  wire  from  the  power 
source with a grounding screw. 

6. 

Reinstall the enclosure. 

7. 

Turn on power supply.  If the wiring is properly connected, 
a  “click”  should  be  heard  and  the  light  will  illuminate  (if  a 
bulb is installed). If there is no response from the Opener, 
check power source and wiring. 

WARNING 

To prevent SERIOUS INJURY or DEATH from electrocution or fire: 
- Power MUST be DISCONNECTED BEFORE proceeding with permanent wiring procedures. 
- Garage Door Opener installation and wiring MUST be in compliance with all local electrical and building 

codes. Make sure the Opener is ALWAYS grounded. 

- NEVER use an extension cord, 2-wire adapter or modify the power plug in any way to make it fit the outlet.

 

Ground screw (green)

 

Conduit with wire

 

Y

 

W

 

Neutral (W)

B

 

Wire nut

 

W

 

Line (B )

 

Ground (G)

 

Ordinary Power Connection

 

Invisible Light Beam

 

15 

WARNING 

To prevent SERIOUS INJURY or DEATH from a closing garage door: 

- The Photo Eye Safety System MUST be installed BEFORE connecting power. 

- The Photo Eye Safety System MUST be properly connected and aligned BEFORE operating the Opener.

 

Содержание 24000-DKO

Страница 1: ...ener WILL NOT CLOSE until the Photo Eye Safety System is properly installed and aligned REGULARLY CHECK and TEST the Opener according to the safety label to ENSURE SAFE OPERATION Retain this manual for future reference Serial __ __ __ __ __ __ __ Date Installed __ __ __ __ __ __ __ __ GDO Manual Revised 05 10 GARAGE DOOR OPENER MODEL 24000 DKO HANDLES DOORS 18 FT WIDE UP TO 7FT TALL Owner s Manual...

Страница 2: ...taching Door Arms 10 Installing Light and Emergency Release Handle 11 Wiring Wiring Instructions 12 Connecting Photo Eye Safety System 13 Connecting Wall Panel 14 Connecting Power 15 Adjustment Aligning the Photo Eye Safety System 15 Travel Limit Adjustment 16 Force Adjustment 17 Final Adjustment and Testing 18 Operation Programming Hand held Transmitter 19 Operating the Opener 20 21 Maintenance 2...

Страница 3: ...ture Safety Labels Chain Photo Eye Safety System Opener Unit Lamp Dome Sprocket Cover Single Button Transmitter Wall Panel Header Bracket Door Bracket Trolley Door Arms Pulley Rail Header Segment Rail Middle Segments x3 INSTALLATION HARDWARE LOCATED IN HARDWARE BAG SHOWN IN ACTUAL SIZE Hanging Brackets Insulated Staples Securing wires x 2 Self Threading Screw 1 4 x 5 8 Door Bracket Trolley Shaft a...

Страница 4: ...7 16 and 1 2 sockets Warranty LIMITED WARRANTY AND LIMITATION OF LIABILITY Decko Products warrants to the first purchaser of this product for the initial residence in which it is installed to be free from defects in materials and or workmanship for a period of 1 YEAR from date of purchase and that the motor to be free from defects in materials and or workmanship for a period of 6 YEARS from date o...

Страница 5: ...le from the Chain carton and lay it beside the rail assembly Hold Cable Eyelet on the end of cable and thread about 20 50cm through the slot on the Header Segment of the rail 2 Insert the Pulley into the opening while the cable is hanging 3 Secure the Pulley by inserting the 3 8 x 1 3 4 Clevis Pin through the top of the rail 4 Lock the Clevis Pin with a Hitch Pin Rotate the Pulley to ensure it spi...

Страница 6: ...door from Opener before adjusting the chain Installing Cable and Chain WARNING To prevent SERIOUS INJURY DO NOT connect power until instructed Keep hands and fingers clear from sprocket during operation Wear gloves when installing chain and cable Keep hands and fingers away from joints and possible sharp edges Cable Chain Fig 1 Fig 2 Fig 3 Sprocket Sprocket Cover 2 Tighten until 1 4 6mm Base of Ra...

Страница 7: ...f necessary Once a year Limit and Force adjustment may be necessary due to weather conditions Refer to pages 16 17 for adjustment Conduct Safety Reverse Test after ANY adjustments Lubricate door rollers bearings and hinges The Opener is permanently lubricated DO NOT lubricate or grease the Opener rail or door tracks Maintenance 22 To Install Header Bracket Note Installation procedures may vary acc...

Страница 8: ... 5 16 carriage bolts washers and nuts not provided as shown in Fig 3 c The length of bolts will depend on the thickness of your door Note DO NOT use Self Threading Screws on a wood door WARNING To Prevent SERIOUS INJURY or DEATH Use Emergency Release to disconnect Trolley ONLY when the door is CLOSED to prevent unexpected rapid falling in case of a unbalanced poor conditioned door Use Emergency Re...

Страница 9: ... Fig 1 shows mounting the Opener directly to structural support on the ceiling Fig 2 and 3 show mounting on a finished ceiling with heavy duty angle iron angle iron not included Determine the mounting option that works best for your application and follow installation steps below 1 Raise the Opener and rail assembly and temporarily place it on a stepladder 2 Position the Opener and rail assembly s...

Страница 10: ...an 20 Transmitters are stored the first stored Transmitter will be replaced i e the 21st Transmitter replaces the 1st stored Transmitter If the courtesy light is already on it will flash once and stay illuminated for 30 seconds If a Transmitter is not accepted the courtesy light will stay on for 30 seconds flash 4 times and then stay on for 2 1 2 minutes Retry programming the Transmitter by repeat...

Страница 11: ...CE A MONTH NO ONE should cross the path of moving door during operation and or testing If either Force or Travel limit adjustment is made the other adjustment may also needed After ANY adjustments to the door system the Safety Reverse Test MUST be performed to ensure the door reverses on contact with a 1 1 2 thick 2x4 laid flat object The Photo Eye Safety System MUST be properly aligned and tested...

Страница 12: ...e size and operating conditions of the garage door will determine the correct level of Force Sensitivity Weather conditions may also affect the operation of the door requiring further adjustments as needed Note If the close force is set too light the Opener will reverse the door during closing If the open force is set too light the Opener will stop the door during opening Note There are 12 levels ...

Страница 13: ...following steps 2 1 If the door is balanced refer to Force Adjustment to adjust Close force 2 2 If the door is unbalanced binding or jammed call a trained service person to adjust the door Adjusting Open Up Travel Limit Adjusting Close Down Travel Limit Stop Bolt Trolley Minimum 2 5cm clearance Open Close 16 Connecting Photo Eye Safety System About the Photo Eye Safety System The Photo Eye Safety ...

Страница 14: ... generates the Invisible Light Beam 2 When properly aligned the Sensor should emit a steady red light when it senses the invisible light beam from the Emitter 3 If the indication is unsteady flashes or is dim check for any obstructions and adjust the position until the Sensor gives a STEADY RED LIGHT Note The path of the invisible light beam MUST NOT be obstructed No part of the garage door or any...

Отзывы: