3.4  NLS 3000 BK08...48-E  

 

Conventional control panel (mimic) 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Width 

111.5  mm 
144 

mm 

176.5  mm 
209 

mm 

241,5  mm 
274 

mm 

BK 08-E 
BK 16-E 
BK 24-E 
BK 32-E 
BK 40-E 
BK 48-E 

Height 

144 

mm  

 

Depth 

60  

mm        + connector  About 130 mm 

Mounting method 

Front panel mounting 

 

Weight 

0,6 kg 

BK 16-E 

 
3.4.1  General 

 

The  "conventional  control  panel"  is  a  communication  slave  within  the  NLS  3000  communication 
system. It serves for display and control of the NLS, enabling lights to be switched on or off. From this 
control panel, the NLS generates visual and audible alarms on faults in the light circuits or in the NLS 
and system power supply. 

 

 

3.4.2  Buttons 

 

Each individual button consists of a button, a status LED arranged above and a labelling field located 
on the left. The labelling field (dimmable) is backlit. Marking of the labelling fields takes place via an 
insertable strip that can be adapted for various projects. 
 

3.4.3  General buttons 

 

For  general  control  of  the  NLS  3000,  permanent  and  configurable  functions  are  implemented.  The 
associated buttons are arranged in the left section of the control panel or directly below of the ship’s 
mimic indication. 
 
 
 
 

Содержание NLS 3000

Страница 1: ...www deckma gmbh de Page 1 of 27 Technical documentation NLS 3000 NAVIGATION LIGHT CONTROL For use on seagoing vessels Change status Version Date Author Checked Remark 0 1 07 08 2008 STO HN 1 Edition 0 2 29 09 2010 STO TK Changes to BK01 E to BK08 48 E 0 3 08 04 2016 TK TK Some small errors corrected 0 4 12 01 2017 TK TK Special function handmade p 21 ...

Страница 2: ...ule 10 11 3 4 BK08 48 E conventional control panel 12 14 3 5 Graphic control panel 15 17 3 6 VM01 E VDR module 18 3 7 SM01 E interface module 19 3 8 DT01 E data module 20 4 0 Operation of NLS 3000 via conventional BK08 48 E 21 22 5 0 Operation of NLS 3000 via graphic BG01 E 23 24 6 0 Mechanical specification 6 1 BK01 E conventional control panel 25 6 2 BG01 E graphic control panel 25 6 3 Control c...

Страница 3: ...e control panels conventional with buttons and LEDs or graphic with touchscreen can be arranged projecting The individual modules are interconnected via a bus cable that supplies the modules with operating voltage The system is organised according to the master slave principle This means that a master module collects the information from the slave modules evaluates and manages the information and ...

Страница 4: ... mimic Ship mimic with 7 LEDs for main lights lanterns Display and switching option for up to 48 individual lights lanterns 4x buttons for special light lantern functions Backlit button labelling field dimmable 2 5 NLS 3000 BG01 E Graphic control panel with touchscreen Graphic control panel with touchscreen control options as on conventional control panel Jpg background images for light lantern po...

Страница 5: ...main module includes a power monitoring circuit The main module also has a connection for an optional data module DT01 E The main module has 10 WEIDMÜLLER connectors for modules supplying a total power of about 4A For conversion of the 230VAC and 115VAC power supplies to the 24V DC internal system supply voltage an option for the connection of two external power supplies is provided 3 1 2 Overview...

Страница 6: ...onal display For easy system analysis and display of nominal and actual values a display board can be added The display is controlled by a microcontroller via an 8 bit databus and RS RW and E clock The buttons on the display board are read in directly via microcontroller ports The display board also has a battery backed real time clock This is connected to the microcontroller via an I2C bus ...

Страница 7: ...tween the two power supplies one switching relay for two lights respectively is arranged downstream of this supply circuit The respective voltage is then distributed between the individual light circuits Each light lantern circuit has a current sensor for two current ranges The first switching operation takes place for currents up to about 200 mA via a shunt the second for currents up to about 4 A...

Страница 8: ...ommunication in constant fault state OK Light status 8 green LEDs Light circuit status without faults Green Light is switched on and values are correct Green flashing Delay after switching on continues until valid A D values are present or overwrite is active DIP switch FAULT Light status 8 red LEDs Light circuit status with faults Red flashing Light fault detected new fault Red Light fault detect...

Страница 9: ...active 3 The selected channel is shown through the OK LED 4 At the same time the lowest byte value from the operating hours counter will be shown through the FAULT LED This indication is here binary coded 5 Push the button LED HOUR a second time the LEDs will show the middle byte from the operating hours counter 6 Push the button LED HOUR a third time the LEDs will show the highest high byte from ...

Страница 10: ...ied jointly for all two lights via JN1 For switching between the two power supplies one switching relay for two lights respectively is arranged downstream of this supply circuit The respective voltage is then distributed between the individual light circuits Each light circuit has a current sensor for two current ranges The first switching operation takes place for currents up to about 200 mA via ...

Страница 11: ...n in constant fault state OK Light status 2 green LEDs Light circuit status without faults Green Light is switched on and values are correct Green flashing Delay after switching on continues until valid A D values are present or overwrite is active DIP switch FAULT Light status 2 red LEDs Light circuit status with faults Red flashing Light fault detected new fault Red Light fault detected fault ac...

Страница 12: ...tion system It serves for display and control of the NLS enabling lights to be switched on or off From this control panel the NLS generates visual and audible alarms on faults in the light circuits or in the NLS and system power supply 3 4 2 Buttons Each individual button consists of a button a status LED arranged above and a labelling field located on the left The labelling field dimmable is back...

Страница 13: ...ng and holding this button switches off the power after around 3 seconds Power status LED Off Power off Green Power on Red flashing No power MAIN or EMGY new fault Red No power MAIN or EMGY fault accepted System status LED Green System without faults Red flashing System fault e g module not accessible Main LED and emergency LED a to Power off status Green Power available Green flashing No power b ...

Страница 14: ...atus button Switches associated function or light on or off Status LED Off Function or light switched off Green Function or light switched on Green flashing Delay after switching on continues until valid A D values are present or overwrite is active DIP switch Red flashing Light fault detected new fault Red Light fault detected fault accepted Mimic Mimic LEDs Off Light switched off On Light switch...

Страница 15: ...S Bus In 15 pin Dsub male JP1 Connection NLS Bus Out 15 pin DSub female JPT1 Supply 24V DC from NLS bus Power consumption 24V max 0 3 A Display visible area 95 4 mm x 53 9 mm Display resolution 480 x 272 pixels Display colours 16 it 65 536 3 5 1 General The graphic control panel is a communication slave within the NLS 3000 communication system It serves for display and control of the NLS enabling ...

Страница 16: ...GY Pressing and holding this button switches off the power after about 3 seconds Power status LED Off Power off Green Power on Red flashing No power MAIN or EMGY new fault Red No power MAIN or EMGY fault accepted System status LED Green System without fault Red flashing System fault e g module not accessible Main LED and Emergency LED a to Power off status Green Power available Green flashing No p...

Страница 17: ...ction Button status Switches associated function or light on or off Status LED Off Function or light switched off Green Function or light switched on Green flashing Delay after switching on continues until valid A D values are present or overwrite is active DIP switch Red flashing Light fault detected new fault Red Light fault detected fault accepted Mimic Mimic LEDs Off Light off On Light on Flas...

Страница 18: ...ng specifications IEC 61162 1 Part 1 Single talker and multiple listeners IEC 61162 100 Extra requirements for the UAIS IEC 61162 102 Extra requirements for the Voyage Data Recorder 3 6 2 VDR interface The microcontroller an ATmega162 with two serial interfaces communicates with the master via one of the interfaces and with the other interface via the alternative driver provided for RS485 or RS232...

Страница 19: ...b male Supply 5V DC Power consumption from 5V supply max 0 005 A Supplied from module 3 7 1 General The slave module serves for connection of the NLS 3000 main module to the ship automation system It decouples both systems 3 7 2 Connector Communication takes place via an RS232 driver module with the main module and via an RS485 module with the ship automation system The interface output to the shi...

Страница 20: ...dent of the higher level system Integration into the system takes place via a special interface 3 8 2 Power supply The module receives its 5V power for supplying the microcontroller via the interface From this voltage 3 3V is generated internally for supplying the SD memory card 3 8 3 Connector Communication takes place via an RS232 driver module The data module is also supplied with 5V operating ...

Страница 21: ...at the NLS is operating without fault and lights red on faults 4 2 LED brightness setting There are eight brightness levels for the individual LEDs and button backlight Provided for this purpose is the Back Light button The brightness is increased one level each time this button is pressed Selection takes place from the highest level to the lowest level When the button is pressed and held these le...

Страница 22: ...this settings The here used touch display is not multi touch capable 4 6 Light buttons Each light is assigned a button in the NLS and can be switched on or off via this button A two colour LED is arranged directly on the right next to the button When the button lights green the associated light is on and the power is in the given range The LED flashes red on faults in the light circuit After accep...

Страница 23: ...upply The SYS LED lights green to show that the NLS 3000 is operating without faults and lights red only on faults 5 2 Backlight brightness setting The display backlight has ten brightness settings Provided for this purpose is the Back Light button The brightness is increased one level each time this button is pressed Selection takes place from the highest level to the lowest level It is also poss...

Страница 24: ...f the maximum permissible operating time is exceeded a fault is generated 5 6 Ship mimic For the main lights display is provided in the form a ship mimic When these lights are switched on the associated LED in the ship mimic also lights up and flashes on faults 5 7 Buzzer The buzzer is controlled via a driver transistor and a microcontroller port circuit The buzzer is located on the back of the co...

Страница 25: ... Tel 49 0 4105 65 60 0 DECKMA GmbH Fax 49 0 4105 65 60 25 E mail info deckma gmbh de Internet www deckma gmbh de Page 25 of 27 6 0 Mechanical specifications 6 1Dimensions of conventional control panel BK 08 48 E 6 2Dimensions of graphic control panel BG 01 E ...

Страница 26: ...PANEL Tel 49 0 4105 65 60 0 DECKMA GmbH Fax 49 0 4105 65 60 25 E mail info deckma gmbh de Internet www deckma gmbh de Page 26 of 27 6 3 Dimensions of control cabinet for up to 16 light circuits 6 4 Dimensions of control cabinet for 17 48 light circuits ...

Страница 27: ...commended for a safe and reliable operation for the complete system Main and emergency power supply unshielded cable min 3x1 5mm Lights lantern outputs unshielded cable min 3x1 5mm Output contacts unshielded cable min 2x0 75mm Control inputs shielded cable min 2x0 75mm VDR output shielded twisted pair 2x2x0 75mm Control panel shielded twisted pair 2x2x0 75mm Approved maximum cable length 500m Depe...

Отзывы: