DW1000 User Manual
© Decawave Ltd 2017
Version 2.12
Page 116 of 242
for details of the optimum selections of SFD sequence.
Sub-Index
Field
Description of fields within Register file: 0x21 – User defined SFD
0
reg:21:00
SFD_LENGTH
This is the length of the SFD
sequence used when the data rate is 850 kbps and
higher. Valid length configuration values must be between 8 and 16 symbol
2
8 ≤ SFD_LENGTH ≤ 16
Register file: 0x1F – Channel Control
) is one,
SFD_LENGTH must be set to either 8 or 16. Other values should not be used.
1
reg:21:01
TX_SSFD_MAGL
(Symbols 7..0)
This field sets the short SFD
magnitude data for the transmitted SFD
sequence,
for the first 8 symbol intervals. The low order bits define the part of the SFD
sequence sent first in time.
2
reg:21:02
TX_SSFD_MAGH
(Symbols 15..8)
This field sets the short SFD
magnitude data for the transmitted SFD
sequence,
for the second 8 symbol intervals. The values here are used when SFD_LENGTH
is greater than 8. Where SFD_LENGTH is less than 16 the low order bits are
applicable up to the specified length.
3
reg:21:03
TX_SSFD_SGNL
(Symbols 7..0)
This field sets the short SFD
polarity data for the transmitted SFD
sequence, for
the first 8 symbol intervals. The low order bits define the part of the SFD
sequence sent first in time.
4
reg:21:04
TX_SSFD_SGNH
(Symbols 15..8)
This field sets the short SFD polarity data for the transmitted SFD sequence, for
the second 8 symbol intervals. The values here are used when SFD_LENGTH is
greater than 8. Where SFD_LENGTH is less than 16 the low order bits are
applicable up to the specified length.
5
reg:21:05
RX_SSFD_MAGL
(Symbols 7..0)
This field sets the short SFD magnitude data for the receive SFD sequence, for
the first 8 symbol intervals. The low order bits define the part of the SFD
sequence sent first in time.
6
reg:21:06
TX_SSFD_SGNH
(Symbols 15..8)
This field sets the short SFD magnitude data for the receive SFD sequence, for
the second 8 symbol intervals. The values here are used when SFD_LENGTH is
greater than 8. Where SFD_LENGTH is less than 16 the low order bits are
applicable up to the specified length.
7
reg:21:07
RX_SSFD_SGNL
(Symbols 7..0)
This field sets the short SFD
polarity data for the receive SFD
sequence, for the
first 8 symbol intervals. The low order bits define the part of the SFD sequence
sent first in time.
8
reg:21:08
TX_SSFD_SGNH
(Symbols 15..8)
This field sets the short SFD polarity data for the receive SFD sequence, for the
second 8 symbol intervals. The values here are used when SFD_LENGTH is
greater than 8. Where SFD_LENGTH is less than 16 the low order bits are
applicable up to the specified length.
9
reg:21:09
TX_LSFD_MAG0
(Symbols 7..0)
This field sets the long (64-symbol) SFD magnitude data for the transmitted SFD
sequence. This byte covers the first 8 symbol intervals, symbols 7 to 0. The low
order bits define the part of the SFD sequence sent first in time.
10
reg:21:0A
TX_LSFD_MAG1
(Symbols 15..8)
This field sets the long (64-symbol) SFD magnitude data for the transmitted SFD
sequence, for symbol intervals 15 to 8.
11
reg:21:0B
TX_LSFD_MAG2
(Symbols 23..16)
This field sets the long (64-symbol) SFD magnitude data for the transmitted SFD
sequence, for symbol intervals 23 to 16.
12
reg:21:0C
TX_LSFD_MAG3
(Symbols 31..24)
This field sets the long (64-symbol) SFD magnitude data for the transmitted SFD
sequence, for symbol intervals 31 to 24.
13
reg:21:0D
TX_LSFD_MAG4
(Symbols 39..32)
This field sets the long (64-symbol) SFD magnitude data for the transmitted SFD
sequence, for symbol intervals 39 to 32.
14
reg:21:0E
TX_LSFD_MAG5
(Symbols 47..40)
This field sets the long (64-symbol) SFD magnitude data for the transmitted SFD
sequence, for symbol intervals 47 to 40.
15
reg:21:0F
TX_LSFD_MAG6
(Symbols 55..48)
This field sets the long (64-symbol) SFD magnitude data for the transmitted SFD
sequence, for symbol intervals 55 to 48.
16
reg:21:10
TX_LSFD_MAG7
(Symbols 63..56)
This field sets the long (64-symbol) SFD magnitude data for the transmitted SFD
sequence, for symbol intervals 63 to 56.