The sixth is [SNR,SS .SSS,SNRR,RRR .RRR<cr>] where:
1 . SNR is the signal to noise ratio for the velocity .
2 . SS .SSS is the velocity of the water .
3 . SNRR is the signal to noise ratio for the level sensor .
4 . RRR .RRR is the distance measurement to the water surface .
The seventh is [DSS .SSS,RRR .RRR<cr>] where:
1 . D is the direction of the water flow and can be "+" or "-" or
"?" if unknown .
2 . SS .SSS is the velocity of the water
3 . RRR .RRR is the distance measurement to the water surface .
The 2nd & 3rd options are "VELOCITY SPECTRUM" and "DEBUG"
The second option is ."Velocity Spectrum" and is designed for
engineering use to calculate the FFT (Fast Fourier Transform) .
The third option is "Debug" and is designed for engineering use
and prints out a list of variables .
• Note: User must send the exact serial number that
matches what is currently programmed into the radar
unit for it to transmit data, otherwise the request will
be ignored . User has the ability to program the serial
number as needed . (In this case the serial number
becomes the MODBUS address of the radar .)
Once new protocols or options have been selected, press the OK
button . The Configure program will save the new settings into
memory and the SVR Dual™ will start each time with these new
settings until you change them again .
4.5 Loading New Firmware & Configuring the SVR D
u
al™
From time to time Decatur Electronics will release new firmware
for the SVR Dual™ . If you have received new firmware then save
the firmware to a file on your hard drive remembering the path to