GENESIS-VPD™ USER’S MANUAL
33
Rev. 09/04
8.4 Power Consumption Parameters
Supply voltage range
6.2VDC – 8.0VDC
All currents measured at 7.2VDC with backlight on.
Standby (antenna off)
.180 amperes
Antenna ON
.370 amperes
(no targets displayed)
Antenna ON
.440 amperes
(“55” target displayed)
Antenna OFF
.180 amperes
(segment check “888 888”)
Antenna ON
(segment check “888 888”)
.370 amperes
All currents measured at 7.2VDC with backlight off.
Standby (antenna off)
.155 amperes
Antenna ON
.345 amperes
(no targets displayed)
Antenna ON
.415 amperes
(“55” target displayed)
Antenna OFF
.155 amperes
(segment check “888 888”)
Antenna ON
(segment check “888 888”)
.345 amperes