![DEC VRT17-W3 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/dec/vrt17-w3/vrt17-w3_operating-instructions-manual_2461356010.webp)
10
By sensing the absence of one or both sync signals coming
from the host computer, it will reduce power consumption
as follows:
This monitor is capable of 3 states of reduced power
consumption.
Power Saving Function
•
If any or both indicator is flashing, please cycle the power
switch once. If they are still flashing, there is a potential
monitor failure.
Please note which function indicator is lit, unplug the AC
cord, and contact your service representative.
•
If there is a signal source input to both video 1 and 2
connectors, the power saving function acts on the input
signal with the higher power consumption as in the table
above.
The H-sync is not present.
The unit goes into standby state.
The V-sync is not present.
The unit goes into suspend state.
Both the H-sync and V-sync are not present.
The unit goes into active-off state.
.
The monitor requires a videocard or screen saver software
which switches off one or both sync signals to activate the
power saving function.
Caution:
The Power Saving function will automatically put
the monitor into the Active-off state if the power
switch is turned on without any video signal
input. Once the horizontal and vertical syncs are
sensed, the monitor will automatically return to
its Normal operation state.
u
(power)
indicator
green on
green on
green on
off
off
Required
resumption time
—
approx. 3 sec.
approx. 3 sec.
approx. 10 sec.
—
1
2
3
4
5
POWER SAVING
indicator
off
orange on
orange on
orange on
off
Power
consumption
≤
140 W
≤
100 W
≤
15 W
≤
5 W
0 W
Power Saving Operation
.
.
State
Normal operation
Standby
(1st step of power saving)
Suspend
(2nd step of power saving)
Active-off
(3rd step of power saving)
Power-off
Mode