SUPER RUNNER SERIES GAS FRYERS 

CHAPTER 1:  INSTALLATION INSTRUCTIONS

 

 

 

1-1

 

1.1 Safety 

Information 

 

Before attempting to operate your unit, read the instructions in this manual thoroughly.  Throughout this manual you will 
find notations enclosed in double-bordered boxes with the symbol 

.   The information contained in the box concerns 

actions or conditions that may cause or result in injury to personnel or damage to your system, and/or cause your system 
to malfunction. 

 

1.2 

General Installation Instructions 

 

 DANGER

 

Building codes prohibit a fryer with its open frypot of hot oil being installed beside an open flame of any 

type, including those of broilers and ranges. 

 

 DANGER

 

This appliance must be installed with sufficient ventilation to prevent the occurrence of unacceptable 

concentrations of substances harmful to the health of personnel in the room where it is installed. 

 

 DANGER

 

No structural material on the fryer should be altered or removed to accommodate placement of the fryer 

under a hood. 

 

 DANGER

 

Single fryers must be restrained to prevent tipping when installed in order to avoid the splashing of hot 

liquid.  The means of restraint may be the manner of installation, such as connection to battery of 

appliances or installing the fryer in an alcove, or by separate means, such as straps or chains. 

 

 DANGER

 

Do not attach an apron drainboard to a single unit.  The appliance may become unstable, tip over, and 

cause injury.  The appliance area must be free and clear of combustible material at all times.

 

 

NOTICE 

This appliance is only for professional use and shall be used by qualified personnel only.

 

 
CLEARANCE AND VENTILATION   

 

This fryer must be installed with a 6-inch (150-mm) clearance at both sides and back when installed adjacent to 
combustible construction.  No clearance is required when installed adjacent to

 

non-combustible construction.  A 

minimum of 24-inches (600-mm) clearance should be provided at the front of the fryer. 

 

The fryer flue opening must not be placed close to the intake of an exhaust fan, and the fryer must never have its flue 
extended in a "chimney" fashion.  An extended flue will change the combustion characteristics of the fryer.  To provide 
the airflow necessary for good combustion and burner operation, the areas surrounding the fryer front, sides, and rear 
must be kept clear and unobstructed. 

 

The fryer must be installed in an area with an adequate air supply and adequate ventilation.  Adequate distances must be 
maintained from the flue outlet of the fryer to the lower edge of the ventilation filter bank.  Filters should be installed at 
an angle of 45°.  Place a drip tray beneath the lowest edge of the filter.  For U.S. installation, NFPA standard No. 96 
states, "A minimum distance of 18-inches (450-mm) should be maintained between the flue outlet and the lower edge of 
the grease filter".  

Frymaster recommends that the minimum distance be 24-inches (600-mm) from the flue outlet to the 

bottom edge of the filter. 

 

INSTALLATION 

 

NOTE:  

Unless special ordered, this fryer is designed for operation at altitudes of 2000 feet (610 meters) and below.  

The unit must be modified for operation above 2000 feet (610 meters).

 

 

 

Содержание SR42 GM

Страница 1: ...ED STATES For Service Call 318 865 1711 Shipping Address 8700 Line Avenue Shreveport Louisiana 71106 Price 10 00 8195999 08 2017 NON CE Super Runner Series Gas Fryers Installation Operation Manual Ser...

Страница 2: ...ending upon the gas line connection Single fryers equipped with legs must be stabilized by installing anchor straps If a flexible gas line is used an additional restraining cable must be connected at...

Страница 3: ...Register Your Warranty Online at http fm hal frymaster com qsys lib cgi lib swr290 pgm...

Страница 4: ...ar of combustible material at all times NOTICE This appliance is only for professional use and shall be used by qualified personnel only CLEARANCE AND VENTILATION This fryer must be installed with a 6...

Страница 5: ...e incoming gas pressure is in excess of PSI 3 45 kPa 35 mbar a step down regulator will be required CE UNITS ONLY Dean Super Runner gas fryers have obtained CE markings for countries and gas categorie...

Страница 6: ...2 40 2 40 1 51 12 0 17 5 22 0 4 8 7 0 8 8 3 BLUE 3 BLUE 3 RED Blue Blue Red 26N 26N 16LP SR prefix Super Runner Series GM suffix gas millivolt system with no electrical supply connections required NO...

Страница 7: ...ryers without depending upon the gas line connections If a flexible gas hose is used a restraining cable must be connected at all times when the fryer is in use NOTE The installation must be inspected...

Страница 8: ...omponents Conversions can only be executed by qualified factory authorized personnel NON CE UNITS ONLY See gas valve illustration below and gas valve burner and orifice location on page 1 6 when perfo...

Страница 9: ...tural Gas Conv Parts 1 8100811 Pilot Orifice 26N 3 8103464 Burner Orifice 2 40mm 42 1 8022530 Label Conversion Date SR52 CE Natural Gas to Propane Conv Parts 1 8102400 Pilot Orifice 16LP 3 8102059 Bur...

Страница 10: ...r Orifice 2 53mm 39 NON CE ONLY SR52 SR62 Series Only Burner Orifice 1 70mm 51 NON CE ONLY SR42 Series Only Burner Orifice 2 80mm 35 NON CE ONLY S42 Series Only Burner orifices listed above are for fr...

Страница 11: ...epress red button to turn the valve off 2 1 2 Pilot Lighting Procedures NOTE This fryer was tested adjusted and calibrated to sea level conditions before leaving the factory Adjustments may be necessa...

Страница 12: ...heating tubes are covered in liquid prior to engaging burners NOTE If solid shortening is used pack the shortening into the frypot ensuring the shortening is packed beneath between and above the tubes...

Страница 13: ...the solution to simmer for 10 15 minutes then drain and rinse the frypot with clean water twice Add cup of white vinegar to the last rinse to neutralize any alkalinity remaining from the detergent Wi...

Страница 14: ...UNIT THERMOPILE HONEYWELL 807 3565 COAXIAL LEAD TO THERMOCOUPLE 812 1284 HIGH LIMIT OPERATING THERMOSTAT HONEYWELL CE PP TH PP TH NON CE UNITS ONLY 30 0 N O COM N C 200 2 5 0 OFF 1C 4C 3C HONEYWELL 1...