background image

 

 
 
 
 
 
 
Flue Connections and Outlets 

 
Dean Croft Clearburn stoves can be flued from the top and the back, or with a vertical back 
box.  Horizontal flue from back of stove should not exceed 150mm. 
All flue connections must be sealed with fire cement. Doors in the register plate must be 
present or a soot box fitted in the back or side of the fireplace to enable access to clean the 
chimney when the stove is installed without a liner.  
If the chimney has been lined and cannot be swept through the stove an access door on the first 
length of flue must be installed for cleaning access. 
 
 
 

        

 

 
        

X

 = Position of baffle plat 

        Y

 = Back protection brick 

 
Diagrams showing from the top (A), back (B) and back box (C) outlet baffle plate position. 
 

Please Note:

 All Profile top stoves use the 6mm black rope seal supplied under the flue spigot 

to bring the flue spigot flush with the stove. 
 

 
 
 
 
 
 
 
 

Содержание Croft Clearburn Junior

Страница 1: ...to the touch and due care will be needed when operating All stoves before being operated must be checked that the installation complies with all local national and European standards Before the stove...

Страница 2: ...with the door about of a turn anti clockwise to open the door Controlling the stove Diagram A Primary air controls on front of door Secondary air control knob between front stove legs The primary air...

Страница 3: ...r about 1 hour Please Note For long periods of burning you will need to use seasoned hard wood Longer periods of burning may cause the door glass to blacken but this can be cleared when you get the fi...

Страница 4: ...give off a metallic smell It is advisable to ventilate the room ie open the windows This will subside fairly quickly after the stove has been burning hot for at least 2 hours The appliances have been...

Страница 5: ...the stove starts to emit fumes into the room 1 Check there is no blockage or restriction in the flue 2 Check the external air vent is not blocked 3 Check the baffle plate has not dislodged itself fro...

Страница 6: ...ied out Health And Safety Precautions All work must be carried out to the requirements Health and Safety at Work Act 1974 There must not be an extractor fan fitted in the room There must be an air ven...

Страница 7: ...imney without a liner the register plate must be fitted with removable doors to facilitate cleaning If its not possible to fit doors in the register plate then a cleaning door will need to be fitted a...

Страница 8: ...he beam or mantle piece from the heat The single wall flue from the top of the stove must be at least 3 times its diameter from combustible materials i e 150 6 flue 450 18 distance Be careful not to p...

Страница 9: ...of the fireplace to enable access to clean the chimney when the stove is installed without a liner If the chimney has been lined and cannot be swept through the stove an access door on the first leng...

Страница 10: ...toves with a kw rating of over 5kw Very air tight properties designed with air permeability less than or equal to 5 0 m3 h m2 per hour an air vent will need to be fitted for all kilowatts It must be c...

Страница 11: ...nd the left hand leg slides down between the first brick and a bar that is welded to the stove Level the main grate B then slide it the rest of the way into the stove The front main grate B should now...

Страница 12: ...fit Remove the blank plate under the door and log retainer Fit grate frame between the bars welded in the bottom of the firebox with the front solid bar of the frame faced forward Fit cast grate into...

Страница 13: ...line 5 2 Croft Clearburn Small 6 6 Croft Clearburn Medium 8 4 Croft Clearburn Large 11 6 Croft Clearburn Small with log store 5 2 Stove Performance Croft Clearburn Small Slimline 6 5kw nominal 79 6 Ne...

Страница 14: ...Clearburn Medium STDFCRM STDFCRML Croft Clearburn Large STDFCRL Description of product Croft Clearburn wood and multifuel heating stove product range Steel bodied stove fitted with cast iron doors Su...

Страница 15: ...0 Wood 0 31 Ancit 0 34 5 3Kw 75 7 Wood 5Kw 66 2 Ancit 6931 SE 2 Croft Slimline 5 STSFCRSL5 Co 13 0 Wood 0 28 Ancit 0 30 5Kw 81 6 Wood 4 9Kw 75 8 Ancit 6042 1 Croft Clearburn Slimline 6 STDFCRSL 6 Co...

Страница 16: ...nstaller for any relevant guarantees applicable to the installation Dean Forge Fabrication Ltd will not be held liable for any consequential or incidental loss damage or injury however caused Claims u...

Страница 17: ...17...

Страница 18: ...astleigh Devon TQ11 0LS PRODUCT REGISTRATION Name Address Phone Number Suppliers Details Name Address Phone Number Installers Details Name Address Phone Number HETAS Registration Number Date of Purcha...

Отзывы: