background image

 

D

ean 

S

toves 

Dean Forge Fabrication Ltd. Dean Prior, Buckfastleigh, Devon TQ11 0LS 

 

T e l:    0 1 3 6 4  6 4 3 5 7 4        

 

w w w.d e a n

–f o r g e.c o.u k     e m a i l:  s t o v e s @ d e a n-f o r g e.c o.u k

 

 

 

Operating Instructions for the Dean Forge Clearburn Range 

(Excluding Junior and Junior SE) 

 
All stoves meet the essential type test requirement BS 
EN13240:2001 + Amd 2:2004, CE marked  

 

 
 
Unpacking Stove 
 

The baffle plate will be found on the base of the stove and will need to be positioned as per 
diagram.  Check position of bricks.  The secondary air control knob will be found inside the 
stove stored with a glove and these instructions and will need screwing on. 

 

 
 Safety Note 
 

Warning- 

The external parts of the appliance will get very hot to the touch and due care will 

be needed when operating. 

 

All stoves before being operated must be checked that the installation complies with all local, 
national and European standards.  
 
Before the stove is first used or when fitting other appliances into the room, please check that 
adequate air vents are in place to cover the requirements of such appliances. 
 

Extractor Fans. 

 When operating an extractor fan in the same room or space as the appliance 

the extractor fan could cause the stove not to function properly and pull dangerous fume into 
the room. This must be checked by a trained qualified engineer before using the stove

 

 
Wood & Suitable fuels 
 

Dry wood, 18% moisture content or below must be used or the stove and flue will tar up 
and the door won’t stay clean. 

Wood is best seasoned by splitting it into a log and dried for 2 years in a covered area allowing 
air to pass through.  Peat can also be used but must be dry. 

Содержание Croft Clearburn Junior

Страница 1: ...to the touch and due care will be needed when operating All stoves before being operated must be checked that the installation complies with all local national and European standards Before the stove...

Страница 2: ...with the door about of a turn anti clockwise to open the door Controlling the stove Diagram A Primary air controls on front of door Secondary air control knob between front stove legs The primary air...

Страница 3: ...r about 1 hour Please Note For long periods of burning you will need to use seasoned hard wood Longer periods of burning may cause the door glass to blacken but this can be cleared when you get the fi...

Страница 4: ...give off a metallic smell It is advisable to ventilate the room ie open the windows This will subside fairly quickly after the stove has been burning hot for at least 2 hours The appliances have been...

Страница 5: ...the stove starts to emit fumes into the room 1 Check there is no blockage or restriction in the flue 2 Check the external air vent is not blocked 3 Check the baffle plate has not dislodged itself fro...

Страница 6: ...ied out Health And Safety Precautions All work must be carried out to the requirements Health and Safety at Work Act 1974 There must not be an extractor fan fitted in the room There must be an air ven...

Страница 7: ...imney without a liner the register plate must be fitted with removable doors to facilitate cleaning If its not possible to fit doors in the register plate then a cleaning door will need to be fitted a...

Страница 8: ...he beam or mantle piece from the heat The single wall flue from the top of the stove must be at least 3 times its diameter from combustible materials i e 150 6 flue 450 18 distance Be careful not to p...

Страница 9: ...of the fireplace to enable access to clean the chimney when the stove is installed without a liner If the chimney has been lined and cannot be swept through the stove an access door on the first leng...

Страница 10: ...toves with a kw rating of over 5kw Very air tight properties designed with air permeability less than or equal to 5 0 m3 h m2 per hour an air vent will need to be fitted for all kilowatts It must be c...

Страница 11: ...nd the left hand leg slides down between the first brick and a bar that is welded to the stove Level the main grate B then slide it the rest of the way into the stove The front main grate B should now...

Страница 12: ...fit Remove the blank plate under the door and log retainer Fit grate frame between the bars welded in the bottom of the firebox with the front solid bar of the frame faced forward Fit cast grate into...

Страница 13: ...line 5 2 Croft Clearburn Small 6 6 Croft Clearburn Medium 8 4 Croft Clearburn Large 11 6 Croft Clearburn Small with log store 5 2 Stove Performance Croft Clearburn Small Slimline 6 5kw nominal 79 6 Ne...

Страница 14: ...Clearburn Medium STDFCRM STDFCRML Croft Clearburn Large STDFCRL Description of product Croft Clearburn wood and multifuel heating stove product range Steel bodied stove fitted with cast iron doors Su...

Страница 15: ...0 Wood 0 31 Ancit 0 34 5 3Kw 75 7 Wood 5Kw 66 2 Ancit 6931 SE 2 Croft Slimline 5 STSFCRSL5 Co 13 0 Wood 0 28 Ancit 0 30 5Kw 81 6 Wood 4 9Kw 75 8 Ancit 6042 1 Croft Clearburn Slimline 6 STDFCRSL 6 Co...

Страница 16: ...nstaller for any relevant guarantees applicable to the installation Dean Forge Fabrication Ltd will not be held liable for any consequential or incidental loss damage or injury however caused Claims u...

Страница 17: ...17...

Страница 18: ...astleigh Devon TQ11 0LS PRODUCT REGISTRATION Name Address Phone Number Suppliers Details Name Address Phone Number Installers Details Name Address Phone Number HETAS Registration Number Date of Purcha...

Отзывы: