background image

30

3.2 Unlocking access to programming

1.  Scroll through the parameters with the buttons  

 and   until the display shows P008;

2.  Access the parameter by pressing the button  ;
3.  The  display  shows  alternately  the  writing 

 to indicate that the control board 

is waiting for the transmission of the unlocking 
code;

4.  Within 10 sec. press the CH1 of the “TX Mas-

ter”,  the  display  shows 

  before 

returning to the list of parameters;

5.  Access to programming is unlocked.

3.3 Unlocking access to programming and global reset

WARNING!        This  procedure  involves  the  loss  of  all 

stored settings.

The procedure allows the unlocking of the control panel without 
having to know its unlocking code.

Following  this  release, 

you  must  program  the  control  panel 

again and adjust all operating parameters, 

in particular, re-

member  to  properly  set  the  configuration  of  parame-
ters (P028 - P029 - P030 – operator configuration)

. You 

will also need to repeat the measurement of impact forces to 
ensure the installation compliance to standards.

1.  Scroll  through  the  parameters  with  the  buttons 

  and 

 

until the display shows P008;

2.  Access the parameter by pressing the button  ;
3.  The display shows alternately the writing 

;

4.  Press  the  button 

,  the  display  shows  the  flashing  writing 

;

5.  Press the button again and hold for 5 seconds (releasing it 

before, the procedure is terminated): The display shows the 
fixed writing 

 followed by 

, before returning to the 

list of parameters;

6.  Access to programming is unlocked.

4

  

Inputs configuration

Where the installation requires different commands and / or additional to 
the standard ones described by plan, you can configure each input for the 
operation desired (eg START, PHOTOS, STOP, etc ...).
1.  Scroll down the parameters with the   and   to see that correspond-

ing to the desired one:

 

  P017=for INPUT 1;

 

  P018=for INPUT 2;

 

  P019=for INPUT 3;

 

  P020=for INPUT 4;

 

  P021=for INPUT 5;

 

  P022=for INPUT 6;

2.  Confirm by pressing on the   key to get access to the parameter (eg. 

P018);

3.  Scroll down with the   and  , keys to set the value corresponding to 

the desired operation (refer to table “Input Configuration parameters” 

on page 33

);

4.  Confirm by pressing on the   key (display shows again P018).
5.  Execute the new connection to the input just reconfigured.

5

  

Programming complete

WARNING

 At the end of the programming procedure, use the buttons   and   until the appearance of the symbol “----”, the 

operator is now ready again for new manoeuvres.

Содержание REV Series

Страница 1: ...Downee Tech Support Operating Instructions REV ...

Страница 2: ...in explosive atmospheres or surroundings that may prove cor rosive and damage parts of the product WARNING To ensure an appropriate level of electrical safety always keep the 230V power supply cables apart minimum 4mm in the open or 1 mm through insulation from low voltage cables motors power supply controls electric locks aerial and auxiliary circuits power supply and fasten the latter with appro...

Страница 3: ...t N 900 1200 450 Work cycle leaf L 8m up to 1000 Kg 27 cycles hour 36 cycles hour up to 1400 Kg 22 cycles hour 31 cycles hour Maximum n of opera tions in 24 hour leaf L 8m up to 1000 Kg 270 300 300 up to 1400 Kg 220 250 250 Built in capacitor µF 18 Operating temperature range C 20 50 C Motor thermal protection C 150 C Opening speed m min 10 12 Weight of product with package Kg 18 Protection degree...

Страница 4: ...on is respected throughout the length Tighten the lock nuts of REV in a robust way Fig 7 and cover with plastic caps 4 3 How to unlock the operator Once you open the lock on the handle protected by a plastic cover the lever must be turned in the direction shown in Fig 8 at this point the operator is unlocked and the gate in the absence of other obstacles is free in his movements The reverse proces...

Страница 5: ... for not self locking operators if P062 3 output for electric lock power supply via external relay if P062 4 output for electro magnets power supply for barriers ifP062 5 or temporized output if P062 5 15 16 17 24 V Flashing light output max 15W art Lumy 24A S 18 19 18 N C Input 6 FCC 1 If it intervenes it stops M1 closing If unused short circuit If the installation requires different comman ds an...

Страница 6: ...LLER N O N O PED N C FCA1 N C RG58 N C START FCC1 TX RX PHOTO 1 OPEN GATE WARNING LIGHT 24V 15w FLASH LUMY 24A S max 15W COM N O COM N O COM N C COM N C COM N C COM N C 2 x 1 mm 2 2 x 0 5 mm 2 2 x 0 5 mm 2 2 x 0 5 mm 2 2 x 0 5 mm 2 2 x 0 5 mm 2 2 x 0 5 mm 2 2 x 0 5 mm 2 2 x 0 5 mm 2 COM N C N O CON1 230V 22V F N TRANSFORMER 230V 22V POWER SUPPLY 230V 50Hz 10 F1 SAFETY Only if needed RED BLUE Brown...

Страница 7: ...P062 4 output for electro magnets power supply for barriers ifP062 5 or temporized output if P062 5 14 15 16 Output 24V max 100mA by selecting the FL WL jumper you can choose the 230 Flash output as a 24V output if the jumper is set to FL or as a Warning light output if jumper set to WL Warning the output capacity allows to use LED flashing lights only 17 18 17 N C Input 6 FCC 1 If it intervenes i...

Страница 8: ...O PED N C FCA1 N C RG58 N C START FCC1 TX RX PHOTO 1 OPEN GATE WARNING LIGHT 230V max 150W 2 x 1 mm 2 2 x 0 5 mm 2 2 x 0 5 mm 2 2 x 0 5 mm 2 2 x 0 5 mm 2 2 x 0 5 mm 2 2 x 0 5 mm 2 2 x 0 5 mm 2 2 x 0 5 mm 2 ENC M1 F N BROWN BLACK GRAY OMNIPOLAR CIRCUIT BRAKER POWER SUPPLY 230V 50Hz 10 L N LUMY A max 40W FLASH 230V 3 x 0 22 mm 2 4 x 1 5 mm 2 3 x 1 5 mm2 COM N C N O SAFETY Only if needed Brown Blue B...

Страница 9: ...ly Inputs status check it s correct Total operations counter see P064 i g 3x100 3000 operations performed Maintenance operations counter see P065 i g 5 x500 2500 operations remaining before the maintenance intervention request manoeuvres counter disabled 3 Hold down the key to display a cyclic 3 options or release the button to exit the parameter 3 Selection type of operators IMPORTANT 1 Scroll do...

Страница 10: ... again P001 6 Motor stroke learning 1 Make sure you have properly adjusted the opening closing limit switches cams 2 Scroll down the parameters with and keys until you visualise P003 3 Access the parameter by pressing the key 4 When flashes continue pressing the key 5 Release the key when stops flashing Start the learning procedure with operator 1 opening 6 Wait for the door searches and stops on ...

Страница 11: ...n a remote control previously learned 8 Adjustment of operating parameters If you need to modify the operating parameters force speedness etc 1 Scroll down the parameters until you visualize the desire pa rameter i g P032 2 Confirm by pressing on the key 3 By pressing on and set up the desired value 4 Confirm by pressing on the key display shows the param eters previously selected For the complete...

Страница 12: ...ey 3 When flashes press the key 4 Release the key as soon as stops flashing Default parameters for the configuration currently in use are restored 5 At the end of the operation display returns to P007 Warning After you restore the default parameters you must program the control panel again and adjust all operating parameters in particular remember to pro perly set the configuration of parameters P...

Страница 13: ... the parameter by pressing the button 3 The display shows alternately the writing 4 Press the button the display shows the flashing writing 5 Press the button again and hold for 5 seconds releasing it before the procedure is terminated The display shows the fixed writing followed by before returning to the list of parameters 6 Access to programming is unlocked 4 Inputs configuration Where the inst...

Страница 14: ...erators mouvement not detected Make sure that operators and encoders connections are well done Check that jumpers J5 and J9 are well positioned as shown on the electric wiring for 24V only If this error appears again replace the control panel 9 START UP The start up phase is very important to ensure maximum security and compliance to regulations including all the requirements of EN 12445 standard ...

Страница 15: ...ure that the motor does not push in the opposite direction the limit switch electri cal connections might be reversed The gate moves by fits and starts it is noisy it stops at half run or it does not start Make sure that nothing hinders the gate wheels movement and the slide in which they roll There always must be backlash between rack and pinion make sure the rack is accura tely positioned The po...

Страница 16: ...OPEN_PM man present open 006 CLOSE_PM man present close 007 ELOCK IN electric lock activation See P062 008 PHOTO 1 photocell 1 009 PHOTO 2 photocell 2 010 SAFETY 1 safety rib 1 011 STOP lock 012 FCA1 opening limit switches Mot1 013 FCA2 opening limit switchtes Mot2 014 FCC1 closing limit switches Mot1 015 FCC2 closing limit switches Mot2 016 SAFETY 2 safety rib 2 IN1 START START INPUT_2 operating ...

Страница 17: ...meter Collectivity function if it is activated it deactivates both opening and closing inputs for the whole duration of automatic opening and closing 000 collectivity function deactivated 001 collectivity function activated Ram blow function it pushes the motors closed for one second before each opening movement so as to ease the electric lock release 000 ram blow deactivated 001 ram blow function...

Страница 18: ...d received use recommended battery powered and or solar panel 000 Energy saving not active 001 Energy saving active Electric lock output operating If 0 boost output for electric lock art 110 power supply If 1 24V output controlled by the ELOCK_IN input as pulsed mode If 2 24V output controlled by the ELOCK_IN input as step by step mode If 3 electro brake output for not self locking operators If 4 ...

Страница 19: ... enabled 001 safety edge enabled only while closing 002 safety edge enabled only while closing and before any movement 003 safety edge enabled only when opening 004 safety edge enabled only while opening and before any movement SAFETY 2 Delay on limit switch detection the operation is stopped after 1 5 sec from limit switch detection When during this delay a stop is detected the operator is sudden...

Страница 20: ......

Страница 21: ...110 223 113 321 388 ...

Страница 22: ...35 45 500 600 400 500 300 400 ...

Страница 23: ......

Страница 24: ...kaniu niebieski Finecorsa magnetico di apertura verde Opening magnetic limit switch green Fin de course magnétique d ouverture vert Final de carrera magnético de apertura verde Fim de curso de abertura magnético verde Wyłączniki krańcowe magnetyczne na otwieraniu zielony FCC 1 FCA 1 A B C A Nero Black Noire Negro Preto Czarny FCA 1 B Blu Blue Bleu Azul Azul Niebieski COM C Marrone Brown Marron Mar...

Страница 25: ...22x22 Cremallera GALVANIZADA 22x22 Cremalheira ZINCADA 22x22 Listwa zębata METALOWA do spawania 22x22 113 126000 Cremagliera ZINCATA 30x12 ZINC PLATED rack 30x12 Crémaillère ZINGUÉE 30x12 Cremallera GALVANIZADA 30x12 Cremalheira ZINCADA 30x12 Listwa zębata METALOWA do przykręcenia 30x12 Pignone Z22 619090 Pignone Z22 per incremento velocità su motori REV Z22 pinion to increase speedness of REV mot...

Страница 26: ...364 8288 See downee com au for your state office Tech Support 1800 241 733 techsupport downee com au downee com au Downee Tech Support Telephone 1800 241 733 Tech Support Hotline 0419 599 982 Email techsupport downee com au ...

Отзывы: