background image

 

 

 

CAL3K-F Installation Guide V5 

2022 

Website: 

www.ddscalorimeters.com

 

Digital Data Systems (Pty) Ltd. 

CAL3K Advanced Bomb Calorimeters 

www.ddscalorimeters.com 

 

2.

 

The Lid stop will also need to be fitted to the back panel of the calorimeter.  

a.

 

First unscrew the back panel as shown in the picture below.  

b.

 

Fit the Lid Stop onto the back panel as shown in the picture below using the screws 

supplied.  

c.

 

Fit the back panel back as indicated in the picture below.  

 

        

 

 

 

 

 

 

 

 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание CAL3K 3K-F

Страница 1: ...3K F INSTALLATION GUIDE VERSION NO 5 DATE 2022 MANUFACTURED BY...

Страница 2: ...EN FILLING 3 3 3 THE 3K 2 AIR COOLER 3 3 4 THE 3K 5 BAYONET VESSEL 4 3 5 THE 3K 3 OXYGEN FILLING STATION 4 4 INSTALLATION 5 4 1 UNPACKING AND INSPECTION 5 4 2 SETTING UP 6 4 2 1 PREREQUISITES 6 4 2 2...

Страница 3: ...calibration But there is more Information and capability This is not explained here but in an ON LINE version It is safe to say that you need a PC or laptop to change from the basic operation to a mor...

Страница 4: ...N MANUAL CAL3K F Installation Guide Printed 1 3K 2 CAL3K Air Cooler 1 3K 2 KT CAL3K Air Cooler Installation Kit 1 Included in Kit 3K 1 055 3K External 12V 1 5A Power Supply 1 3K 3 CAL3K Filling Statio...

Страница 5: ...meter and the lid is closed The rest is automatic Width 270mm Height 200mm Depth 380mm Weight 8kg Power 220 240V 12W 3 3 THE 3K 2 AIR COOLER The air cooler requires no water piping or other resources...

Страница 6: ...ed as a Pressure Vessel and is consequently tested by an inspection authority to 10 times its normal pressure Diameter 63mm Height 150mm Weight 2kg 3 5 THE 3K 3 OXYGEN FILLING STATION The oxygen filli...

Страница 7: ...s in this document 3 Inspect everything for any physical damage during transit If damaged consult your Agent immediately 4 The Calorimeter has a GROUND SAFETY EARTH lug at the rear panel This lug MUST...

Страница 8: ...le will also be required balance cable supplied as part of kit 4 2 2 SITE SELECTION The 3K F Calorimeter is a desktop unit which can be installed wherever the laboratory space permits with two restric...

Страница 9: ...nal The reason we ship the lid unlatched is due to customs purposes If customs officials wish to inspect inside the CAL3k F calorimeter the lid is locked therefore we have to ship with the lid and lat...

Страница 10: ...eters www ddscalorimeters com 2 The Lid stop will also need to be fitted to the back panel of the calorimeter a First unscrew the back panel as shown in the picture below b Fit the Lid Stop onto the b...

Страница 11: ...he gauge block side If the oxygen bottle is not situated close to the Filling Station or if it is in another room or perhaps outside then a solid permanent installation of pressure piping should be in...

Страница 12: ...ressure is 30bar 3000kPA which is the standard for bomb calorimetry Do not use any tools to open or close the vessel If the vessel fails to deflate use the pre scribed emergency deflate procedure as o...

Страница 13: ...FACTORY THE VESSEL MUST BE INSPECTED AT REGULAR INTERVALS DEPENDING ON THE USE A SUITABLE INSPECTION PERIOD CAN BE SET By your agent AND THE UNIT WILL ISSUE AN INSPECTION WARNING AND SOON AFTER THIS...

Страница 14: ...De filler cap only part number 3K 3 22 Do not use any oil or grease on any of the oxygen fittings or the O rings A very small amount of high pressure vacuum grease is allowed on the O ring to make th...

Страница 15: ...the authorised Dealer to which he she returns the unit is proven to be defective Replacement of a defective part will be made only within the applicable warranty period of 12 twelve months from date o...

Страница 16: ...in 100 working order It is the Owner s responsibility to inspect any repaired product on receipt thereof and confirm in writing any faults errors or problems with the said product If a fault error or...

Страница 17: ...________________________________________ DATE INSTALLED ____________________________ REPRESENTATIVE OF DEALER AGENT CUSTOMER ORDER NUMBER AND DATE _______________________________________ INSTALLATION...

Отзывы: