Keypad Functions

The keypad on the rear of the unit provides the installer access to:
Listen to the current IP address or reset it to a default IP and subnet MASK address. Make test 
calls and control speaker level during the call.

Making a test call.

To test if the unit has been successfully registered, press ‘

D’

 to loop the line, then dial the 

number required plus #. If all is well, a connection will be made.
Press 

D

 again to go off line. If the line is engaged or the other party hangs up the unit will 

automatically disconnect.
Calling a phone by its IP address can be done by entering a * between each group of digits 
and the port number. IE, if a phone you wish to call is on IP 

192.168.1.117:5060

, type

D 192*168*1*117*5060 #

. (note not all phones can be called using this technique).

If the default port is 5060 for the remote phone, then it may not be required when calling.

Get current IP address;

During standby, press ‘

C

’ on the rear keypad to retrieve the current IP address.

The address will continue to repeated, press ‘D’ to end the cycle and return the unit to 
standby mode.

Resetting the IP address

To reset the address, connect the power (via the power jack or Ethernet PoE lead).
Wait about 10-20 seconds, 
then enter  

*# *# 7*1,

 this will set address mode to 

Static 

the IP address to 192.168.1.100, 

set the subnet mask to 255.255.0.0 and clear the Administration Password.
OR enter 

*# *# 7*2, 

this will set address mode to Dynamic IP and also clear the admin 

password. 

Volume control   ‘B’ & ‘C’

During conversation, the speaker volume may be increased by pressing 

B

 or decreased by 

pressing 

C

. These adjustments only remain as set for the duration of the call and do not 

affect the default level.
To set the default level refer to 

System Settings

 on page 11.

Содержание Sentry VOIP V2

Страница 1: ...NTION UARD G MK III Doorstation ON OFF ENTRY Doorstation S PRESS THEN DIAL NUMBER PRESS TO END CALL 1 2 WXY ABC 3 DEF 5 JKL 8 QZ 0 6 MNO 9 4 GHI 7 PRS TUV 1 2 WXY ABC 3 DEF 5 JKL 8 QZ 0 6 MNO 9 4 GHI...

Страница 2: ...ntrol Logging in NetWork setup Voice Menu Call Functions SIP Proxy Settings Warning Specifications 5 5 Programming 6 6 7 8 9 10 Phone Number Menu 13 Pcb Layout 17 Specifications 18 18 18 Connection De...

Страница 3: ...Weather shielded optional optional door gate release DDC VoIP FEATURES PRODUCT INFORMATION HELP POINT TELEPHONE Model DDC VoIP The Sentry VoIP Doorstation is an ethernet connected telephone and provid...

Страница 4: ...ol The DDC_VoIP phone is currently ship fitted with one relay as standard the second relay on request The remote operator may activate the on board relay s by entering the code set for that relay For...

Страница 5: ...an be called using this technique If the default port is 5060 for the remote phone then it may not be required when calling Get current IP address During standby press C on the rear keypad to retrieve...

Страница 6: ...login page select one of the following Settings Menu to set network and telephone parameter Button Call Number Assignment to set the phones number for each button input Dial Plan telephone number mas...

Страница 7: ...required to restart by logging in using the new IP address Do not click on go back one page of the browser usually in the top left corner In most cases the DNS Server IP can remain set to Auto DNS in...

Страница 8: ...0ms 15 2 iLBC 30ms 13 3 Speex 2 15 24 6 G 729 8 If the iLBC or SPEEX codecs are used then set the following for each a iLBC codec select the frame size your network requires to 20mS or 30mS b SPEEX co...

Страница 9: ...s and PIN are supplied by the ISP Network administrator this information is case sensitive and should be typed in correctly The User Name is relayed to the connecting IP telephone as a caller ID and i...

Страница 10: ...e numbers if the other party is busy or doesn t answer To enable this function enter the Divert Numbers and set the Outgoing No Answer Period the a value in second the phone should wait for a pickup b...

Страница 11: ...ered by pressing the B and C key on the back of the unit to increase or decrease the level respectively Set the Ringer Volume level to suit site conditions The onboard relay may be activated remotely...

Страница 12: ...server and the protocol used is SYSLOG Although generally on a Linux and Unix systems SYSLOG programmes can be sought for the Windows system as well Each event is timed stamp with the phone ID and IP...

Страница 13: ...long phone numbers like an IP address to enable silence dialling click Yes to the option Dial numbers silently in the System section see page 9 Special commands within the phone number The DDC_VoIP un...

Страница 14: ...tails When making a call numbers that are accepted must match one of the groups above Digits 0 to 9 that are shown in each group will be tested whereas the x within the group indicates that any digit...

Страница 15: ...and MPG 3 files etc need to be converted before it is loaded into the unit Conversion programs are available that can do this CoolEdit pro is a good example The sound file used MUST comply with the f...

Страница 16: ...source There are two methods that power can be supplied from a Ethernet Switch Mode A supply power over the Tx Rx pair TX pair pins 1 2 and RX pair pins 3 6 Mode B via the spare pairs 4 5 and 7 8 pin...

Страница 17: ...J7 J15 SPK MIC HANDSET EXT SPEAKER EXT MIC BUTTON INPUTS bank1 bank2 LCD PORT LK1 AND LK2 Relay linked for normally closed contacts Relay linked for normally open contacts LK1 and LK2 relay links are...

Страница 18: ...ohms speaker relay contacts switching maximum 1A 60Vdc 40Vac SELV or TNV non inductive load voltage free outputs temperature operating range 0 C to 50 C SPL ringer output level 80dBa 1 metre 32 steps...

Страница 19: ...can not be used for emergency purposes during power failure unless fitted with a backup 12 volt battery AND network connection guaranteed 90mm 57mm Speaker Box Dimensions Length 97 mm Width 83 mm Heig...

Страница 20: ...elephones Emergency Telephone Systems Emergency Services Telephones Industrial Telephones Hygienic Environment Telephones Freeway Telephones Rugged Environment Telephones Hotel Telephones Prisoner Tel...

Отзывы: