M O T I O N F E E D B A C K B O A R D M A N A G E R
SET AMPLITUDE
1) Enter (9) to change Amplitude
2) To change the Oscillator amplitude, enter the bit multiplier. The bit
multiplier, which is an integer, is determined by the following formula:
Amplitude = (bit multiplier) X (mV/bit)
Model
Number
Output Scaling
(mV/bit)
Examples
Bit
Multiplier
Resultant
Amplitude
Bit
Multiplier
Range
IX
8.8 mVrms/bit
1.0032 Vrms = (114) X (.0088)
114
1.0032 Vrms
0 - 255
IA
135.0 mVrms/bit
26.0550 Vrms = (193) X (.135)
193
26.0550 Vrms
0 - 255
IB
635.0 mVrms/bit 115.5700 Vrms = (182) X (.635)
182
115.5700 Vrms
0 - 210
*IC
17.6 mVrms/bit
4.0128 Vrms = (228) X (.0176)
228
4.0128 Vrms
0 - 255
*
Note:
Consult factory for IC option. (minimum orders apply)
Data Device Corporation