M O T I O N F E E D B A C K B O A R D M A N A G E R
READ ANGLE INFORMATION
1) Type the code for the desired operation in the
Enter Option:
field
(1 to read Angles ), and hit
Enter
.
2) The test results for the selected operation will be displayed in the console
application screen.
Figure 29. Console Application Test Results for Read Operation
3) The following information is displayed for a read Angles operation.
This example is for a card with six channels installed.
ANGLE:
Channels 1 to 6 position information is continuously updated for
monitoring. Enter (1) to read angles.
BITE:
Channels 1 to 6 BIT (Built-in-test) flag is displayed to insure data is valid.
A BIT will occur if there is a Loss of Signal (ALL inputs), Loss of reference
or if the error exceeds 100 LSB's.
TURNS:
Monitors number of turns for channels 1 to 6. Enter (7) to reset counters.
DIRECTION:
Monitors channels 1 to 6 ("Up" = increasing angle, and "Down" =
decreasing angle).
Data Device Corporation
SB-3621X Manual
29